摘要 清河再生水厂规模为8万m3/d,是目前我国最大的以膜处理技术为核心的再生水厂,采用超滤膜—活性炭工艺处理城市污水处理厂二级出水,最终出水用于生活杂用及景观水体补水。介绍了工艺的设计、调试运行情况,该工艺运行稳定,自动化程度较高,对悬浮物及胶体颗粒的去除能力强,有助于提高再生水水质。 Qinghe Wastewater Reclamation Plant is the largest one in China, which consisted of ultrafilter membrane and granular activated carbon processes to treat the secondary effluent of a wastewater treatment plant in Beijing. The maximum inlet flow is 80 000 m^3/d. Final outlet water of this facility is used as landscape water and urban reuse. The design and practice parameters are introduced in this paper. The process is running steadily with high autoimmunization, and the high removal efficiency of suspension and colloid articles are accepted. These are help to improve the quality of reclaimed water,
出处 《给水排水》 CSCD 北大核心 2008年第2期32-35,共4页 Water & Wastewater Engineering
关键词 再生水 超滤 活性炭 膜处理 Reclaimed water Ultrafiltration Granular activated carbon Membrane
  • 相关文献

参考文献6

二级参考文献10

  • 1韦伯J 上海市政工程设计院 译.水质控制物理化学方法[M].北京:中国建筑工业出版社,1980.60.
  • 2Adin A, Katzhendler J, Alkaslassy D Ch. Ray- acha trihalomethane formation in chlorinated drinking water: a kinetic mode[ J ]. Wat Res, 1991,25 ( 7 ) : 797 - 805.
  • 3Murphy B, Amy G, Siddiqui M. Ozone- induced conversion of DBP precursors (DOC) to biodegradable byproducts (BIXX;)[A]. AWWA 1993 Annual Conference Proceedings (Water Quality) [C]. 1993.
  • 4钟淳昌,给水排水,1997年,23卷,9期,5页
  • 5岳舜琳,中国给水排水,1997年,13卷,增刊,35页
  • 6山村弘之,膜,1995年,20卷,5期,309页
  • 7Wang L,J Japan Water Works Association,69卷,5期,35页
  • 8董秉直,曹达文,范瑾初,李景华,徐强.混凝和粉末炭去除黄浦江水中DOM的效果[J].中国给水排水,2000,16(3):1-4. 被引量:39
  • 9陈洪斌,庞小东,高廷耀,庞玉宝,杨树青.炼油厂污水回用处理研究[J].环境科学学报,2002,22(5):570-575. 被引量:25
  • 10董秉直,曹达文,范瑾初,李景华,徐强.UF膜过滤天然原水阻力特性的研究[J].水处理技术,2001,27(2):80-83. 被引量:21

共引文献73

同被引文献61

引证文献9

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部