期刊文献+

电感耦合等离子体质谱法测定中低合金钢中痕量铝 被引量:1

ICP-MS Determination of Trace Amount of Aluminum in Medium and Low Alloy Steels
下载PDF
导出
摘要 应用电感耦合等离子体质谱法测定了中、低合金钢中痕量铝,并对质谱仪的工作条件作了优化。用微波加热消解技术对样品进行前处理,用混合比例为3比1比1的浓硝酸、浓盐酸及浓氢氟酸的混合酸作为溶解酸。对微波炉的操作程序及参数作出详细叙述。此方法的检出限为w(Al)1.9×10-6%,对浓度水平为w(Al)1.4×10-4%的试样进行精密度试验,其结果的标准偏差值均小于6.0%。 ICP-MS was applied to the direct determination of trace amount of aluminum in medium and low alloy steels, and analytical parameters of the instrument were optimized. Digestion technique assisted with microwave heating was used in the sample pretreatment with an acid mixture of conc. HNO3, conc. HCl and conc. HF in a ratio of 3 to 1 to 1 by volume. The operation programe and parameters of the microwave oven were described in detail. Detection limit (n= 11) of this method was found to be w(Al) 1.9×10^-6%,. Precision tested at the concentration level of w(Al) 1.4×10^-4 % gave RSD values of less than 6%.
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2008年第2期115-118,共4页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 电感耦合等离子体质谱法 试样的微波加热消解 痕量铝 中、低合金钢 ICP-MS Microwave heated sample digestion Aluminum Medium and low alloy steel
  • 相关文献

参考文献9

  • 1GB223.9-1989钢铁及合金化学分析方法[S].
  • 2ISO9658-1990钢铁化学分析方法[S].
  • 3胡净宇,王海舟.ICP-MS在冶金分析中的应用进展[J].冶金分析,2001,21(6):27-32. 被引量:19
  • 4Coedo A G, Dorado M T, Padilla L. Evaluation of different sample introduction approaches for the determination of boron in unalloyed steels by inductively coupled plasma mass spectrometry[J]. Spectrochim Acta, 2005,60B:73-79.
  • 5Yang C H, Jiang S J. Determination of B, Si, P and S in steels by inductively coupled plasma quadrupole mass spectrometry with dynamic reaction cell[J]. Spectrochim Acta, 2004,59B(9):1389.
  • 6Takeshi Yamane, Yusuke Kouzaka, Mie Hirakawa Continuous flow system for the determination of trace boron in iron and steel utilizing in-line preconcentration/separation by sephadex column coupled with fluorirnetric detection[J]. Talanta, 2001,55:387-393.
  • 7Hu Jingyu, Liu Zheng, Wang Haizhou. Determination of trace silverin supralloys and steel by ICP-MS [J]. Anal Chim Acta, 2002,451(2):329-335.
  • 8Douglas Goltz, Michael Boileau, Gundars Reinfelds. Electroerosion of metal in aqueous solution for sample introduction into an inductively coupled plasma mass spectrometer[J]. Spectrochim Acta, 2003, 58B: 1325- 1334.
  • 9黄志勇,经媛元,杨妙峰,孟庆祥,王小如.ICP-MS测定茶叶中微量元素含量及其溶出特性的研究[J].厦门大学学报(自然科学版),2003,42(5):621-625. 被引量:60

二级参考文献13

共引文献77

同被引文献11

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部