摘要 对ng/L级超痕量汞测定中的消解、测定各步骤对灵敏度的影响进行了研究。得出结论:采用高纯氩气作载、屏气,选择高负压值和高扩展倍率能明显提高灵敏度;选择合适的消解时间和缩短测定时间能使灵敏度略有提高;试剂和玻璃器皿所带给空白的痕量汞对提高灵敏度不利,应作除汞处理。 The nanogram level ultra trace analysis of mercury in water is affected by the different steps of disple and determination.Research on it and draw a conclution:Using the high purity argon as the carrying and shielded gas,adopting the high negative voltage and the high extensive multiple,can raise the sensitivity notably.Selecting the dispel time suitably and shortening the determination time probably can raise the sensitivity slightly.The trace mercury from the reagent and glass appliance has a unfavourable influence in raising the sensitivity.Must eliminate it.
出处 《中国环境监测》 CAS CSSCI CSCD 北大核心 1997年第2期22-25,共4页 Environmental Monitoring in China
关键词 痕量分析 灵敏度 水质监测 mercury,fluorescence analysis,mercury analyzer,trace analysis,sensitivity