摘要 对几种凝汽器及真空系统漏入空气流量测量方法进行了比较,分析了各种方法的优、缺点和现场实施的可行性,建立了一种新的漏入空气流量测量方法,并在300 MW机组上实际应用,效果较好。该方法解决了实际运行机组现场测量漏入空气流量及抽气设备抽吸空气流量测量问题,为研究空气对凝汽器和抽气设备性能影响奠定了基础,也为抽气设备现场性能试验提供了一种新的思路。 A comparison of several measuring methods for flow rate of air leaking into condenser and vacuum system has been carried out, the advantages and disadvantages of each method and feasibility of its implementation in the field being analysed, and a new method for measuring flow rate of air leaking into condenser and vacuum system being created. The new mthod has been practically used on 300 MW units, obtaining better results. The new method solved the problems of measuring the flow rate for leaking- in air and that of extracting air in the air- extracting equipment at the field of units' practical operation, laying a foundation for studying the influence of air upon the performace of condenser and of the air - extracting equipment, and providing with a new idea for testing the performace of air - extracting equipment at the field.
出处 《热力发电》 CAS 北大核心 2008年第2期56-58,共3页 Thermal Power Generation
关键词 300 MW机组 凝汽器 真空系统 漏入空气 流量测量 300 MW unit condenser vacuum system leaking- in air flow rate measurement
  • 相关文献

参考文献4

二级参考文献9

  • 1李勇,曹祖庆.凝汽器清洁率的概念及测试方法[J].汽轮机技术,1995,37(2):73-76. 被引量:53
  • 2曹辉玲 等.检漏技术扩其在电力工业的应用[Z].电子工业部第十二研究所,..
  • 3史剑戟.凝汽器真空严密性的几个问题[A]..大功率汽轮机组辅机学术年会论文集[C].上海电力学院,..
  • 4齐复东 等.电站凝汽器设备和冷却系统[M].北京:水利电力出版社,..
  • 5[苏]Бэ卡别洛维奇 任曙译.汽轮机设备的运行[M].北京:水利电力出版社,1975..
  • 6田鹤年.用“气体状态系数法快速计算抽气器空气流量”中国电机工程学会大功率汽轮机组辅机学术年会论文集.1999.9.
  • 7干昌琦 田鹤年.射水抽气器试验[J].江苏电力,1985,3.
  • 8干昌琦,田鹤年.凝气器漏入空气量的计算与试验研究[J].电站辅机,2000,21(3):46-50. 被引量:17
  • 9李勇,曹祖庆.200MW汽轮机多背压运行的热经济性分析[J].热能动力工程,2001,16(2):138-140. 被引量:9