摘要 建立工况可调屏蔽室:安装恒温恒湿系统,实现温度在(10~35)℃连续可调、测量空间温度场均匀度和最大波动均<1℃,湿度控制在(30~60)%范围。利用工况可调屏蔽室,研究温湿度对传导骚扰测试结果的影响:选取电动工具、空调(变频、定频)、除湿机等产品,研究不同产品传导骚扰电压与谐波随环境温湿度的变化规律,发现骚扰电压和谐波测量值随环境温度的变化有很大的不同,试验证明这些产品的传导骚扰电压和谐波测量值明显随着环境温度而变化。研究结果对提高实验室电磁兼容测试水平具有良好的实用价值,对于相关标准的制修订具有参考价值。 An shielding chamber with regulating climatic setting is installed: the temperature can be continuously regulated between (10-35)℃ with the maximum fluctuation of less than 1℃ and the uniform field in the testing room with a deviation of less than 1℃; the relative humidity is controlled between (30-60) %. By taking advantage of this chamber, a study of influence of climatic setting on test data of conducted disturbance is carried out on those appliances like electric tools, air conditioners (frequency-modulating type and invariable-speed type) and dehumidifiers, it is validated that the test data of disturbance voltage and current harmonics are obviously varied at different climatic settings,This study makes a practical impact on EMC laboratories tO improve EMC testing setting, it is alsoa valuable reference to modify the relevant standards.
出处 《环境技术》 2008年第1期35-39,45,共6页 Environmental Technology
关键词 工况可调屏蔽室 电源端传导骚扰 谐波电流 环境温度 受试设备 shielding chamber with regulating climatic setting, conducted disturbance at power termnals, current harmonics, surrounding temperature,equipment under test
  • 相关文献

参考文献2

  • 1国家电力公司武汉高压研究所,山西电力科学研究院,上海电动工具所等.GB17625.1-2003电磁兼容限值谐波电路发射限值(设备每相输入电流≤16A)[s].北京:中国标准出版社,2003.
  • 2上海电动工具所,广州电器科学研究院.GB 4343.1-2003电磁兼容家用电器、电动工具和类似器具的要求第1部分:发射[s].北京:中国标准出版社,2003.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部