摘要
针对新安装的罗斯蒙特质量流量计投用时出现零点漂移的情况,分析了产生漂移的原因,并提出了具体的解决方法。
According to the phenomenon that there is zero drift in the application of newly fixed quality flow-meters Rosmonte, the paper analyzes the reasons of causing zero drift and then puts forward some specific solutions to the above problem.
出处
《石油工业技术监督》
2008年第2期39-40,共2页
Technology Supervision in Petroleum Industry
关键词
质量流量计
零点漂移
科里奥利
quality flow-meters
zero drift
Coriolis phenomenon