回归分析方法在商场建筑节能评价中的应用 被引量:3

Application of Regression Analysis on Evaluation of Energy Efficiency in Shopping Malls
下载PDF
导出
摘要 针对重庆市7座商场建筑的能耗调研结果,应用回归分析方法,研究了室外月平均温度与建筑月能耗、室外月平均温度的平方与建筑月能耗之间的线性回归方程,建立了重庆市商场建筑的参考回归模型;分析了重庆市商场建筑线性回归模型的回归系数的可接受区间;对这7座商场建筑进行了能效评价和节能潜力的分析,为建筑节能改造提供了参考。 Based on the results of energy survey from 7 shopping malls in Chongqing, analysized the lineal regression of building energy consumption per unit floor area vs. the mean monthly outdoor temperature and the lineal regression of building energy consumption per unit floor area vs. the square of the mean monthly outdoor temperature. Presents the reference regression model of the shopping malls in Chongqing. Discussed the accepatale ranges of lineal regression coefficients for evaluating the energy efficiency of shopping malls in Chongqing. Energy efficiency and potentials of these 7 shopping malls are also analysized.
出处 《制冷空调与电力机械》 2008年第1期25-29,共5页 Refrigeration Air Conditioning & Electric Power Machinery
关键词 商场 能耗 室外温度 回归模型 节能 shopping mall energy consumption model efficiency outdoor temperature linear regression model
  • 相关文献

参考文献3

  • 1薛志峰,江亿.商业建筑的空调系统能耗指标分析[J].暖通空调,2005,35(1):37-41. 被引量:45
  • 2JOSEPH CLAM, DANNY H W LI. Electricity consumption cbaracteristics in shopping malls in subtropical climates[J]. Energy Conversion & Management , 2003,44: 1391 - 1398.
  • 3SAT, PAUL SHING KEE.Use of thermal performance line for assessing and controlling energy performance of commercial buildings in Hong Kong [D]. Hong Kong: Hong Kong Polytechnic University,2003.

二级参考文献17

  • 1(美)希阿拉 卡伦德 著 编译.建筑师设计手册,建设部建筑设计院[M].北京:中国建筑工业出版社,1990..
  • 2朱伟峰.[D].北京:清华大学,2001.
  • 3Caecavelli D, Gugerli H. TOBUS-a European diagnosis and derision-making tool for office building upgrading.Energy and Buildings, 2002, 34: 113 - 119.
  • 4Deng Shi-Ming, Burnett J. A study of energy performance of hotel buildings in Hong Kong. Energy and Buildings, 2000, 31: 7- 12.
  • 5Lee W L, Yik F W H. A strategy for prioritizing interactive measures for enhancing energy efficiency of air-conditioned buildings. Energy, 2003, 28: 877 - 893.
  • 6Yu Philip C H, Chow W K. Energy use in commercial buildings in Hong Kong. Applied Energy,2001 (69):243 - 255.
  • 7ASHRAE Standard 90A-1980. Energy conservation in new building design.
  • 8Lee W L, Yik F W H. Regulatory and voluntary approaches for enhancing energy efficiencies of buildings in Hong Kong. Applied Energy, 2002 (71) :251 - 274.
  • 9Dodier R H, Kreider J F. Detecting whole building energy problems. In: ASHRAE Trans. 1999, 105(1). 579-592.
  • 10Bruhns H, Steadman P. A database for modeling energy use in the non-domestic building stock of England and Wales. Applied Energy, 2000 (66) : 277 -297.

共引文献44

同被引文献37

引证文献3

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部