摘要 针对工作-背景区空调(TAC)系统所特有的工作区与背景区间的热环境差异,通过借助评价暂时热感觉的"相对热指标("RWI)及"热损失率("HDR)对使用这种空调系统房间在不同区域及不同温度下的热感觉进行了分析。特别是针对人员在背景区停留时间短这一特点,着重分析了背景区的暂时舒适性,给出了建议的背景区温度设计值,为以后工作-背景区空调系统的设计提供参考。 Aims at the difference of thermal condition between task and ambient area,analysed the thermal sensation under different areas and different temperatures by RWI (Relative Warmth Index)and HDR (Heat Deficit Rate )in the room using task/ambient air-conditioning system.Especially aim at the character that the stopping time in ambient area is short,emphatically analyzed the temporary comfort in ambient area,gave suggestion of the ambient area temperature design value. It may provide the reference for the design of task/ambient air-conditioning system.
出处 《制冷空调与电力机械》 2008年第1期39-42,共4页 Refrigeration Air Conditioning & Electric Power Machinery
关键词 工作区 背景区 相对热指标 热损失率 热感觉 task area ambient area RWI HDR thermal sensation
  • 相关文献

参考文献5

二级参考文献29

  • 1-.地铁一号线工程[M].上海科学技术出版社,1998..
  • 2王晓夏.广州地铁空调系统节能探讨.地下铁道文集[M].海天出版社,1999..
  • 3清华大学热能系 北京地铁公司环境处.北京地下铁道热环境状况的测定与分析总结报告[M].,1986..
  • 4Tuddenham D. Design considerations for a floor-based air-conditioning system with modular services units atthe new Hong Kong Bank Headquarters. In: ASHRAE Trans,1985 b, 91(2). 387- 403.
  • 5Sodec F. The underfloor air supply system- the European experience. In:ASHRAE Trans, 1990, 96(2).
  • 6Faulkner D, Fisk W J, Sullivan D P.Indoor airflow and pollutant removal in a room with desktop ventilation. In:ASHRAE Trans, 1993,99(2). 750 - 758.
  • 7Arens E, Xu T, Miura K, et al. A study of occupant cooling by personally controlled air movement. Energy and Buildings, 1998,27(1):45 - 59.
  • 8Tsuzuki K, Arens E A, Bauman F S,et al. Individual thermal comfort control with desk-mounted and floor-mounted task/ambient conditioning( TAC ) systems. Proceedings of INDOOR AIR '99, Scotland. 1999.
  • 9Faulkner D, Fisk W J, Sullivan D P,et al. Ventilation efficiencies of task/ambient conditioning ,systems with desk-mounted air supplies.Proceedings of INDOOR AIR ' 99 Scotland. 1999,8.
  • 10Zhao Rongyi, Xia Yizai, Li Jun. New conditioning strategies for improving the thermal environment. Proceedings of International Symposium on Building and Urban Environmental Engineering, Tianjin. 1997. 6- 11.

共引文献46

同被引文献8

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部