详细地分析了膨胀水箱在空调水系统中连接点位置的不同对系统水压分布产生的不同影响,从而为工程施工中膨胀水箱的合理利用提供了科学依据,以确保系统安装达到设计、运行要求。
It analyses the different affection of different link location of expanding water tank in air-conditioning water system to the distribution of system water pressure, and this supplies scientific reference to the reasoable utility of expanding water tank in project construction, to assure the system setting meet the need of design and operation.
出处
《山西建筑》
2008年第8期199-200,共2页
Shanxi Architecture
关键词
膨胀水箱
连接位置
水压分布
重要影响
安装