摘要
本论文论述了怀柔自来水厂计算机集散控制系统的最优调度策略,目的是实现取水单耗最低,达到经济可靠运行。每口井的单位电耗定期地被计算,并用起泡排序法排序,根据排序结果构造一个电耗队列。进而,建立一个就绪堆栈,当停止一口井时,该井号被压入堆栈栈顶。当要启动一口井时,就从堆栈栈顶取得井号投入运行。
The paper states the optimal Schcduling Strategy of Computcr Distributed Con-trol System for HUAIROU Waterworks. Its Target is-to minimize the Unit power con-sumption and to achieve economical & reliable running. The unit power consumption forcvery well is calculated and sorted according to the bubble sorting method at regular inter-vals. A power consumption queue is constructed by the sorted results, moreover, A readystack is treated, when a well is stopped, the well number is pushed into the top of the readystack, ir it is required that a well should be started up, then the number of the well is pop-ped from the top of the ready stack.
出处
《北京建筑工程学院学报》
1997年第3期60-65,共6页
Journal of Beijing Institute of Civil Engineering and Architecture
关键词
水厂
集散控制系统
取水
最优调度
Waterworks
Computer
Distributed Control System
Pump Water
Unit power Consumptipn
Ophmize
Scheduling Stratege