地下建筑不同机械补风条件对排烟效果的影响 被引量:3

The effect on smoke evacuation With a mechanical makeup air of underground construction
下载PDF
导出
摘要 地下商业建筑必须通过设置机械补风和机械排烟来控制火灾发生时烟气的流动,以达到人员安全疏散的目的。以某一大型地下建筑的一个防火分区为基础,对其在相同的排烟条件下,不同机械补风条件的排烟效果进行了数值模拟分析,指出了要达到良好的排烟效果的条件。 Underground commercial buildings must be completed by setting up machinery and mechanical exhaust air to control the smoke movement in fire ,so as to achieve the purpose of the safety evacuation. Based on a fire prevention cent area in aunderground commerical building, this study is aimed at the effect on smoke evacation with a mechanical makeup air. The numerical simulations are applied to analyse the characters of fire smoke movement in underground construction. Meanwhile, the numerical simulations evaluate the effect on smoke evacution. Analying this ,it is suitable that the rate of mechanical makeup air is not more than 2 m/s.
作者 王梁波
机构地区 昆明市消防支队
出处 《消防科学与技术》 CAS 2008年第3期192-194,共3页 Fire Science and Technology
关键词 机械补风 机械排烟 地下建筑 数值模拟 排烟 方式 mechanical makeup air mechanical smoke evacuation undeground construction numerical simulations method of smoke evacuation
  • 相关文献

参考文献7

  • 1GB50045-95(2005年版),高层民用建筑设计防火规范[S].
  • 2McGrattan, K. Fire Dynamics simulator (Version 4 ) technical reference guide [ S ]. National Institute of Standards and Technology Special Publication 1018,2005.
  • 3McGrattan, K and G Forney. Fire dynamics simulator (Version 4) user's guide[S]. National Institute of Standards and Technology Special Publication 1019,2005.
  • 4Kashef, A. A computational and experimental study of fire growth and smoke movement in large spaces in CFD 2002[C]. The Tenth Annual Conference of the Computational Fluid Dynamics Society of Canada. Windsor: NRCC,2002.
  • 5C J Macartney, G D I.ougheed, E J Weckman. CFD investigation of balcony spill plumes in atria[C]. In 12th Annual Conference of the CFD Society of Canada, Combustion and Smoke Management. Ottawa,2004.
  • 6J Hietaniemi,S Hostikka, J Vaari. FDS simulation of fire spread-comparision of model results with experimental data [R]. VTT Working Papers. VTT Information Service,2004.
  • 7张梅红,陈立民.地下商场防排烟设计补风方案研究[J].消防科学与技术,2007,26(4):402-403. 被引量:4

二级参考文献1

  • 1NFPA 92B-2005.Standard for Smoke Management Systems in Malls,Atria and Large Spaces[S].

共引文献104

同被引文献15

  • 1杨其新.国内外隧道消防方法及火灾实例调研报告[R].成都:西南交通大学土木工程学院,1996..
  • 2Quintiere J G. Scaling applications in fire research[J]. Fire Safety Journal, 1989,15(1) :3--29.
  • 3Jae Seong Ro h, Hong Sun Ryou, Dong Hyeon Kim. Critical velocity and burning rate in pool fire duringlongitudinal ventilation [J].Tunnellinga- nd Underground Space Technology ,2007,22:262--271.
  • 4AS 4391 -- 1999, Smoke management system-- Hot smoketest[S].
  • 5Poreh, M. and S. Trebukov. Wind effects on smoke motion in buildings [ J ]. Fire Safety Journal, 2000,35 ( 3 ) : 257-273.
  • 6Tominaga, Y., et al., AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings[ J]. Journal of Wind Engineering and Industrial Aerodynamics, 2008,96( 10-11 ) : 1749-1761.
  • 7Emmerich, S. J. , Use of computational fluid dynamics to analyze indoor-air quality issues, 1997, National Institute of Standards and Technology: Gaithersburg, Maryland, USA[S].
  • 8McGrattan, K. , S. Hostikka, and J. Floyd, Fire Dynamics Simulator (Version 5 ) User "s Guide, 2009, National Institute of Standards and Technology : Gaithersburg, Maryland, USA. p. 140[S].
  • 9Association, N. F. P., NFPA 92B, Guide for Smoke Management Systems in Malls, Atria and Large Areas, 2000: Quincy, MA, USA[S].
  • 10韩涛.地下工程火灾发生特征与防护对策研究[J].山西建筑,2008,34(4):209-210. 被引量:12