介绍了电厂循环水系统的基本数据和运行方式对循环水流量调节的局限性。通过试验阐述循环水泵在不同温度和机组负荷下进行双循环泵运行改单循环泵运行的比较。在比较数据及结论的基础上提出建议。
The basic data of the power plant circulating water system are presented, as well as the limitation of the operational mode to the circulating water flow adjustment. Through experiments, the double pump operation mode was compared with the single pump operation mode under different temperatures and different loads. Suggestions are proposed based on that.
出处
《华东电力》
北大核心
2008年第2期41-44,共4页
East China Electric Power
关键词
循环泵
汽轮机
超临界机组
厂用电率
circulating pump
steam turbine
supercritical unit
service power consumption rate