期刊文献+

间接淋巴造影在血管疾病诊断中的应用 被引量:1

Value of indirect lymphography in diagnosis of vascular disease
下载PDF
导出
摘要 采用间接淋巴造影对15例疑有淋巴水肿的下肢血管病患者进行了形态学观察,造影结果所有患者均存在不同程度的淋巴形态学改变或淋巴管不显影,可能的原因是小腿深静脉高压或淋巴管发育畸形。结果表明下肢血管病可合并淋巴回流障碍,间接淋巴造影是一种简便、安全、可重复的检测方法。 Fifteen patients with various forms of vascular disease in the leg were studied by indi rect lymphography. Isovist-300 used for intradermal infusion is a new non-ionic、 water-soluble contrast media. Characteristic patterns of lymphatics were demonstrated. The cause of lymph vessel morphologic change complicated by vascular disease is still unknown The disorders of lymph drainage are possibly due to deep venous hypertension or lymph vessel hypoplasia. Our results indicated that indirect. Lym phography is simple and can be performed repeatly. It has important significance for the differential diag nosis of the vascular disease in the leg.
出处 《临床外科杂志》 1997年第5期266-267,共2页 Journal of Clinical Surgery
关键词 间接淋巴造影 淋巴水肿 深静脉功能不全 Indirect lymphography Iymphedema Deep venous incompetence
  • 相关文献

参考文献3

共引文献32

同被引文献18

  • 1Guermazi A, Brice P, Hennequin C, et al. Lymphography: an old technique retains its usefulness. Radiographics, 2003, 23 (6): 1541-158.
  • 2Moghimi SM, Bonnemain B. Subcutaneous and intravenous delivery of diagnostic agents to the lymphatic system:applications in lymphoscintigraphy and indirect lymphography. Adv Drug Deliv Rev, 1999, 37 (1-3) : 295-312.
  • 3Suga K, Yamamoto S, Tangoku A, et al. Breast sentinel lymph node navigation with three-dimensional interstitial multidetector-row computed tomographic lymphography. Invest Radiol, 2005, 40 (6) : 336-342.
  • 4Dunne AA, Schmidt A, Kuropkat C, et al. The auricular VX2 carcinoma-an animal model for sentinel node concept. In Vivo, 2003, 17 (5): 457-461.
  • 5Suga K, Ogasawara N, Yuan Y, et al. Visualization of breast lymphatic pathways with an indirect computed tomography lymphography using a nonionic monometric contrast medium iopamidol: preliminary results. Invest Radiol, 2003, 38 (2): 73-84.
  • 6Mclntire GL, Bacon ER, Toner JL , et al. Pulmonary delivery of nanoparticles of insoluble, iodinated CT X-ray contrast agents to lung draining lymph nodes in dogs. J Pharm Sci, 1998, 87 (11): 1466-1470.
  • 7Harika L, Weissleder R, Poss K, et al. MR lymphography with a lymphotropic T1-type MR contrast agent: Gd-DTPA-PGM. Magn Reson Med, 1995, 33 (1):88-92.
  • 8Trubetskoy VS, Frank K, Whiteman KR, et al. Stable polymeric micelles: lymphoangiographic contrast media for gamma scintigraphyand magnetic resonance imaging. Acad Radiol, 1996, 3 (3) : 232-238.
  • 9Zhou Z, Guo J, Yu H, et al. Comparison of Gd [DTPA-bis (2-aminoethoxy) ethane] polymeric contrast agent with gadodiamide injection for interstitial MR lymphography: experimental study with rabbits. J Magn Reson Imaging, 2005, 22 (3) : 361-367.
  • 10Ishiyama K, Motoyama S, Tomura N, et al. Visualization of lymphatic basin from the tumor using magnetic resonance lymphography with superparamagnetic iron oxide in patients with thoracic esophageal cancer. J Comput Assist Tomogr, 2006, 30 (2) : 270-275.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部