乳管镜在多孔乳头溢液诊断及治疗中的应用价值 被引量:10

Application of Fiberoptic Ductoscopy in Diagnosing and Treating Multiple Ductal Nipple Discharge
下载PDF
导出
摘要 目的:探讨乳管镜在双侧多孔乳头溢液诊断和治疗中的应用价值。方法:对29例双侧多孔乳头溢液患者进行乳管镜检查,发现乳管内肿瘤者给予手术治疗,对积乳症、乳管扩张症、闭塞性乳管炎患者给予经乳管镜介入治疗。结果:29例(79孔乳管)中,乳管内肿瘤者11例(乳管),占病例总数的(占所检乳管数)37.93%(13.92%),血性溢液11例中乳管内肿瘤9例,非血性溢液18例中乳管内肿瘤2例;切除病灶准确率100%,术后病理诊断符合率88.89%。结论:乳管镜检查有其直观性,术前定位准确,避免了手术的盲目性或切除范围过大;多数患者或乳管,尤其积乳症、闭塞性乳管炎及乳管扩张症的患者或乳管,经过经乳管镜冲洗及介入治疗可达到彻底治愈。 Objective: To explore the value of fiberoptic ductoscopy in diagnosing and treating bilateral muhiple ductal nipple discharge. Methods: Twenty-nine patients with bilateral, multiple duetal nipple discharge were examined by fiberoptic ductoscopy. Those patients with intraduetal papilloma were Ireated through surgery and those with galaelostasia, mammary ducteetasia and obstructive galactophoritis were treated by fiberoptic ductoscopy. Results: Of the 29 cases, there were 11 cases with intraductal papilloma (37.93%). Of the 11 patients with bloody nipple discharge, 9 were diagnosed as intraduetal papilloma. Of the 18 patients with non- bloody nipple discharge, 2 were diagnosed as intraduetal papilloma. All lesions were resected and 88.89% of the preoperative diagnosis were consistent with the postoperative pathological diagnosis. Conclusion: Fiberoptic ductoscopy has many advantages such as direct-viewing and aecuracy. Mosl of the patients with galactostasia or mammary duct ectasia or obstructive galaetophoritis can be cured by fiberoptie duetoscopy.
出处 《中国肿瘤临床》 CAS CSCD 北大核心 2008年第5期245-248,共4页 Chinese Journal of Clinical Oncology
关键词 乳管镜 多孔乳头溢液 诊断 治疗 Ductoscopy Multiple ductal nipple discharge Diagnosis Trealment
  • 相关文献

参考文献11

二级参考文献31

  • 1许娟,王颀,张安秦,施军涛,李文萍,陈中杨.乳管镜临床应用800例[J].中国微创外科杂志,2004,4(4):285-286. 被引量:41
  • 2张振东,李树玲.乳腺癌全乳腺切片的病理组织学研究:Ⅲ.伴发病变和癌旁病变[J].中华肿瘤杂志,1993,15(1):20-22. 被引量:14
  • 3刘巍,李树玲,傅西林.乳腺增生性病变与其癌变的观察Ⅱ免疫组织化学研究[J].中国肿瘤临床,1996,23(10):695-699. 被引量:11
  • 4李树玲 李云英 等.T0乳腺癌74例(77例次)检诊经验[J].中国肿瘤临床,1988,15(3):136-140.
  • 5浅越辰男.早期乳腺癌的诊断[J].日本治疗学会志,1987,22(9):2202-2202.
  • 6Okazaki A, Hirata K, Okazaki M, et al. Nipple discharge disorders: current diagnostic management and the role of fiber-ductoscopy. Eur Radiol, 1999, 9:583-590.
  • 7Shen KW, Wu J, Lu JS, et al. Fiberoptic ductoscopy for breast cancer patients with nipple discharge. Surg Endosc, 2001,15:1340-1345.
  • 8Matsunaga T, Ohta D, Misaka T, et al. Mammary ductoscopy for diagnosis and treatment of intraductal lesions of the breast. Breast Cancer, 2001,8:213-221.
  • 9Dietz JR, Crowe JP, Grundfest S, et al. Directed duct excision by using mammary ductoscopy in patients with pathologic nipple discharge. Surgery, 2002,132:582-587.
  • 10Nishiguchi T,Hishimoto T,Funahashi S,et al.Clinical usefulness of carcinoembryonic antigen measurement in nipple discharge as an adjunctive tool for diagnosis of breast cancer[J].Rinsho Byori,1992,40(1):67-72.

共引文献131

同被引文献74

引证文献10

二级引证文献53

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部