A model for aerosol mass concentration using an optical particle counter 被引量:11

A model for aerosol mass concentration using an optical particle counter
原文传递
导出
摘要 A model for measuring aerosol mass concentration by an optical particle counter is presented using the conception of the average mass. In this model, to understand the meaning of the pulse height distribution of particles which is used to inverse mass concentration, the relationship among intensity distribution in the optical sensing volume, particle shape, and the pulse height distribution is discussed. To solve the instability of the equivalent factor, a novel two-step calibration method is proposed. The experimental results demonstrate that mass concentrations calculated by the model are in good agreement with those measured by a norm-referenced instrument. For samples of soot and air, the slopes of fitting lines of data points are 0.9582 and 0.9220, and the correlation coefficients are 0.9991 and 0.9965, respectively. A model for measuring aerosol mass concentration by an optical particle counter is presented using the conception of the average mass. In this model, to understand the meaning of the pulse height distribution of particles which is used to inverse mass concentration, the relationship among intensity distribution in the optical sensing volume, particle shape, and the pulse height distribution is discussed. To solve the instability of the equivalent factor, a novel two-step calibration method is proposed. The experimental results demonstrate that mass concentrations calculated by the model are in good agreement with those measured by a norm-referenced instrument. For samples of soot and air, the slopes of fitting lines of data points are 0.9582 and 0.9220, and the correlation coefficients are 0.9991 and 0.9965, respectively.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第3期214-217,共4页 中国光学快报(英文版)
基金 the Doctor Creation Foundation of Nanjing University of Science and Technology
  • 相关文献

参考文献8

  • 1Y.C.Chan,R.W.Simpson,G.H.McTainsh,P.D. Vowles,D.D.Cohen,and G.M.Bailey. Atmospheric Environment . 1997
  • 2M.Brauer,C.Avila-Casado,T.I.Fortoul,S.Vedal,B. Stevens,and A.Churg. Environmental Health Perspec- tives . 2001
  • 3A.Thomas,and J.Gebhart. Atmospheric Environment . 1994
  • 4P.G(?)ner,,D.Bemer,and F.FabriCs. Journal of Aerosol Science . 1995
  • 5H.Tang,X.Sun,and G.Yuan. Chin.Opt.Lett . 2007
  • 6F.Gu,J.Yang,B.Bian,and A.He. Laser Technology . 2007
  • 7F.Gu,J.Yang,B.Bian,and A.He. Acta Opt.Sin . 2007
  • 8.Method for determination of inhalable particulate mat- ter(PM10)in air of public place-light scattering method[].National Standard of the People‘s Republic of China(WS/T-).