期刊文献+

螺钉数目对钢板应变及结构刚度的影响 被引量:7

The Influence of the Number of Screws on Bending Stiffness and DCP Strain in an in Vitro Fracture Model
下载PDF
导出
摘要 目的探讨螺钉数量对钢板应变和结构刚度的影响。方法三十根栗木条,随机分成5组,螺钉固定位置:A组固定1、6;B组固定1~2、6;C组固定1~3、6;D组固定1~4、6;E组固定1~6。进行三点折弯实验,实验数据行统计分析。结果A、B、C、D及E组各样本其结构刚度、钢板中央应变无显著差异(P〉0.05),但A组样本钢板表面总的应变比其它组总的应变大(P〈0.05),其余组间两两比较无差异。结论已定钢板长度及工作长度,螺钉数目对钢板中央应变及抗弯刚度无明显影响,但钢板总应变随螺钉数目的减少而增加。 Objective To investigate the effect of the number of screws on the bending stiffness and dynamic compression plate(DCP)strain in an in vitro transverse fracture model. Methods Thirty wooden sticks of the chestnut were separated into five groups at random, Screw position of the five groups were:A 1,6;B 1~2,6;C 1~3,6;D 1~4,6;E 1~6. Thirty plate-screw constructs were test respectively, all strain readings of plate, were compared each other. Results No significant difference about the bending stiffness and median plate strains in three point bending whilst the total plate strains in A were significantly higher than those in the other groups(P〈0.0S). Conclusion This study showed that the symmetrical omission of screws, with a given plate length and working length, would not affect significantly the bending stiffness and median plate strain while the total plate surface strains might increase.
出处 《江西医学院学报》 CAS 2008年第1期29-32,共4页 Acta Academiae Medicinae Jiangxi
关键词 动力加压钢板 钢板应变 抗弯刚度 螺钉数目 三点折弯 dynamic compression plate plate strain the bending stiffness the number of screws three-point bending
  • 相关文献

参考文献10

  • 1郑南生,张光强,姚伦龙.加压钢板治疗股骨干骨折30例失败原因分析[J].中国矫形外科杂志,1998,5(1):37-37. 被引量:4
  • 2赵文志,刘迎曦,张军,李宝文,杨梁.加压钢板固定术后内植物失败的生物力学分析[J].医用生物力学,2003,18(1):50-54. 被引量:13
  • 3Karl S,Ulkich D,Gwidon S,et al. How can Stability in Locked Internal Fixators be Controlled? [J]. Injury, 2003,34 : 11-19.
  • 4Cheals E J, Hayes W C, White A A, et al. Three-dimensional Finite Element Analysis of a Simplified Compression Plate Fixation System[J]. J Biomech Eng, 1984,106 : 295-301.
  • 5Thomas E,Craig A B,Richard F K. Screw Position Affects Dynamic Compression Plate Strain in an in Vitro Fracture Model [J]. J Orthop Trauma, 2001,15(5) : 333-337.
  • 6Xu X X,Zhang X,Liu J G,et al. Stress Analysis after Femoral Shart Osteotomy Fixed by Various Plates Different Rigidities in Simulation Test[J]. Chin Med J(Eng 1), 1993,106(2) : 127- 131.
  • 7John R, Field J R, Hearn T C, et al. Pressure Sensitive Filmstudy on the Effect of Screw Omission Bone-plate Interface Mechanics in Cadaveric Bone[J]. Verterinary Comparative Orthopedics and Traumatology, 1997,10:205-209.
  • 8Dennis J, Sanders R, Milne T, et al. Minimal VS Maximal Compression Plating of the Ulna:a Biomechanical Study of in Direct technique[J]. J Orthop Trauma, 1993,7 : 152-153.
  • 9Roy S, Haidukewych G, Milne T, et al. Minimal Versus Maximal Plate Fixation Techniques of the Ulna:The Biomechanical Effect of Number of Screws and Plate length[J]. J Orthop Trauma,2002,16(3) : 166-171.
  • 10Karl S. Oblique Screws at the Plate Ends Increase the Fixation Strength In Synthetic Bone Test Medium [J]. J Orthop, 2004,18:611-616.

二级参考文献8

共引文献15

同被引文献36

引证文献7

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部