摘要
在弱酸性介质中,利用间接碘量法消除还原物的干扰,于酸性条件下采用直接碘量法测定碘酸钾含量。根据硫代硫酸钠的还原性,以甲醛消除亚硫酸盐的干扰,加过量碘,间接法测定硫代硫酸钠。
The interference of reductant is eliminated by indirect iodimetry in the weak acidic medium and the content of potassium iodate is determined by direct iodimetry under acidic condition.According to the reducibility of sodium thiosulfate,the interference of sulfite is eliminated by formaldehyde and sodium thiosulfate is determined by indirect iodimetry with addition of excessive iodine.
出处
《中国井矿盐》
CAS
2008年第2期45-48,共4页
China Well and Rock Salt
关键词
碘酸钾
氧化性
直接碘量法
硫代硫酸钠
还原性
间接碘量法
Potassium iodate
oxidation
direct iodimetry
sodium thiosulfate
reducibility
indirect iodimetry