摘要 在建立焙烧炉沥青烟气净化系统中冷却水系统故障树的基础上,运用故障树定量分析理论,建立了冷却水系统可靠性定量评价体系,对该系统发生故障的概率作出判断,从而能够及时、合理地确定冷却水系统的状况,以便及时采取应变措施,保持系统可靠运行. Based on the fault tree of the cooling water system in asphalt gas decontaminating for carbon calciner, quantified evaluating system of reliability of cooling water system is set up by using of quantified analysis theory of fault tree. Fault probability can be judged by using it, the state of cooling water system can be fixed in time and in reason, and proper measure can be made to keep the system reliably running.
机构地区 中原工学院
出处 《中原工学院学报》 CAS 2008年第1期29-34,共6页 Journal of Zhongyuan University of Technology
关键词 沥青烟气 净化 冷却水系统 可靠性 定量评价 asphalt gas decontaminating gooling water reliability quantified evaluating