流式细胞仪自动化检测在微核试验中的应用 被引量:3

原文传递
导出
作者 滕晶晶
出处 《安徽预防医学杂志》 2008年第1期33-36,共4页 Anhui Journal of Preventive Medicine
  • 相关文献

参考文献24

  • 1Mavournin KH, Blakey DH, Cimino MC, et al. The in vivo micronucleus assay in mammalian bone marrow and peripheral blood. Mutat Res, 1990 ;239:29 - 80.
  • 2Nusse M, Kamer J, Flow cytometric analysis of micronucleus found in cells after irradiation. Cytometry, 1984;5 (1) :20.
  • 3Schreiber GA, Beisker W, Nusse M, et al. An automated flow cytometric micronucleus assay for human lymphocytes. Int J Radiat Biol, 1992,62(6) :695.
  • 4Nusse M, Beisker W, Kramer J, et al. Mensurement of micronuclel by flow cytometry, Mutagenis, 1994.
  • 5Grawe J, Zetterberg G, Amnous H. Flow cytometric enumeration of micronucleated polychromatic in erythrocytes in mouse peripheral blood. Cytometry, 1992,13(5).
  • 6Grawe J, Zetterberg G, Amnous H. Effects of extended low -dose -rate exposure to 137cs detected by flow -cytometric enumeration of micronucleated erythrocytes in mouse peripheral blood. Int J Radiat Biol, 1993,63(3) : 339.
  • 7Rennie CM, Tompson D, Parker AC, et al. Human erythrocyte fraetionationin " percoll" density gradients. Clin Chim Aeta, 1979,98( 1 ) :119.
  • 8Lahdetie J, Grawe J. Flow cytometric analysis of micronucleus induction in rat bone marrow polychromatic erytheocytes by 1,2,3,4 - diepoxybutance, 3,4 - eposy - bl - butene, and 1,2 - epoxybutance - 3,4 - diol [ J ]. Cytometry. 1997,28 ( 3 ) : 228 - 235.
  • 9Crswell KA, Krishna G, Zielinski D, et al. Use of acridineorange in: flow cytometlc assessment of micronuclei in duction[J]. Murat Res. 1998,414( 1 - 3) : 63 - 75.
  • 10Abuamsson Zetterberg L, Zetterberg G, Bergqvist M, et al. Human cytogenetic biomonitoring using flow - cytometric analysis of micronuclei in transferrin - positive immature peripheral blood reticulocytes [ J ]. Environ Mol mutagen. 2000,36( 1 ) :22 -31.

二级参考文献34

  • 1曹佳,MichaelNusse,WolfgangBeisker,Ilse-DoreAdler.流式细胞术对小鼠外周血红细胞微核自动化检测的研究[J].癌变.畸变.突变,1994,6(6):11-17. 被引量:7
  • 2Hutter K J, Stohr M. Rapid detection of mutagen induced micronucleated erythrocytes by flow cytometry. Histochemistry, 1982, 75(3) : 353-362.
  • 3Torous DK, Hall NE, Dertinger SD, et al. Flow cytometric enumeration of micronucleated reticulocytes: high transferability among 14 laboratories.Environ Mol Mutagen, 2001,38(1): 59-68.
  • 4Weaver JL, Torous D. Flow cytometry assay for counting micronucleated erythrocytes: development process. Methods, 2000, 21(3): 281-287.
  • 5Tometsko AM, Torous DK, Dertinger SD. Analysis of micronucleated cells by flow cytometry. 1. Achieving high resolution with a malaria model.Mutat Res, 1993, 292(2) : 129-135.
  • 6Dertinger SD, Torous DK, Hall NE, et al. Malaria-infected erythrocytes serve as biological standards to ensure reliable and consistent scoring of micronucleated erythrocytes by flow cytometry. Mutat Res,2000,464(2) :195 - 200.
  • 7Grawe J, Nusse M, Adler ID. Quantitative and qualitative studies of micronucleus induction in mouse erythrocytes using flow cytometry. I.Measurement of micronucleus induction in peripheral blood polychromatic erythrocytes by chemicals with known and suspected genotoxicity.Mutagenesis, 1997, 12(1): 1-8.
  • 8Weaver JL, Torous D.Flow cytometry assay for counting micronuclested erythrocytes: development process[J] .Methods, 2000; 21 (3): 281-287.
  • 9Dertinger SD, Chen Y, Miller rk, et al.Micronucleated CD71 - Positive reticulocytes: a blood-based endpoint of cytogenetic damage in humans [J] .Mutat Res.2003; 542 (1-2); 77-87.
  • 10Hutter KJ, Stohr M. Rapid detection of mutagen induced microuncleated erythrocytes by flow cytometry [J] .Histochemistry, 1982; 75 (3) :353- 362.