期刊文献+

Analysis of characteristics of a pneumatic miniature robotic system

Analysis of characteristics of a pneumatic miniature robotic system
下载PDF
导出
摘要 This paper described the structure of a flexible miniature robotic system which can move in humancavities,and then analyzed the characteristics of the robotic system in detail.The mobile mechanism ofthe miniature robotic system is soft;it makes inchworm-like movement driven by a 3-DOF pneumatic rub-bet actuator and holds its positions by air chambers.The driving characteristic models in axial and bend-ing directions of the actuator were set up and the kinemics equations of the robotic system were set up.Experiments had been done through an electro-pressure control system,by which the pneumatic roboticsystem can be controlled with high accuracy.It is suitable for moving in human cavities for medical in-spection. This paper described the structure of a flexible miniature robotic system which can move in human cavities, and then analyzed the characteristics of the robotic system in detail. The mobile mechanism of the miniature robotic system is soft; it makes inchworm-like movement driven by a 3-DOF pneumatic rubber actuator and holds its positions by air chambers. The driving characteristic models in axial and bending directions of the actuator were set up and the kinemics equations of the robotic system were set up. Experiments had been done through an electro-pressure control system, by which the pneumatic robotic system can be controlled with high accuracy. It is suitable for moving in human cavities for medical inspection.
出处 《High Technology Letters》 EI CAS 2008年第1期35-39,共5页 高技术通讯(英文版)
基金 the High.Technology Research and Development Programme of China(No.2004AA404013)
关键词 微型机器人 气动橡胶执行机构 特征分析 空腔 miniature robotic system, pneumatic rubber actuator, characteristic analysis
  • 相关文献

参考文献2

二级参考文献12

  • 1Sondergaard S, Karason S, Wiklund J, et al. Alveolar pressure monitoting: an evaluation in a lung model and in patients with acute lung injury[J]. Intensive Care Medicine, 2003, 29(6): 955 -962.
  • 2Karason S, Sondergaard S, Lundin S, et al. Continuous on-line measurements of respiratory system, lung and chest wall mechanic ventilation [J]. Intensive Care Medicine, 2001, 27(8) : 1328 -1339.
  • 3Guttmann J, Kessler V, Mols G, et al. Continuous calculation of intratracheal pressure in the presence of pediatric endotracheal tubes [ J ].Critical Care Medicine, 2000, 28(4): 1018-1026.
  • 4Sondergaard S, Karason S, Hanson A, et al. Measurement of Intratracheal pressure in pediatric respiratory monitoring [ J ]. Pediatric Research, 2002, 51(3): 339-345.
  • 5Karason S, Sondergaard S, Lundin S, et al. Direct tracheal airway pressure measurements are essential for accurate and safe monitoring of dynamic respiratory mechanics[J]. Acta Anaesthesiologica Scandinavica, 2001,45(2) : 173 -179.
  • 6Fukuda T, Hosokai H, Uemura M. Rubber gas actuator driven by hydrogen storage alloy for in-pipe inspection mobile robot with flexible structure[ A]. Proceedings of the IEEE International Conference on Robotics and Automation[C]. Piscataway, USA: IEEE, 1989. 1847- 1852.
  • 7Chou C-P, Hannaford B. Static and dynamic characteristics of McKibben pneumatic artificial muscles [ A ]. Proceedings of the IEEE International Conference on Robotics and Automation [ C ]. Piscataway,USA: IEEE, 1994. 281-286.
  • 8Suzumori K, Likura S, Tanaka H. Applying a flexible microactuator to robotic mechanisms [ J ]. IEEE Transactions on Control Systems Technology, 1992, 12(2) : 21 -27.
  • 9Nunn J F.应用呼吸生理学[M].北京:科学出版社,1983.
  • 10高立明,林良明,颜国正,戎荣.医学机器人的进展[J].中国医疗器械杂志,1997,21(6):341-344. 被引量:5