摘要 目的:探讨多层螺旋CT肺动脉成像中使用高浓度、低剂量对比剂的可行性。方法:40例被检查者分为两组,A组为采用300mgI/ml对比剂,剂量为100ml、生理盐水30ml;B组为采用400mgI/ml对比剂,剂量为60ml、生理盐水30ml。注射流速均为4ml/s,行胸部肺动脉同层动态扫描,计算肺动脉主干峰值时间(time to peak)、强化峰值(peak contrast enhancement)以及强化CT值大于200HU起始时间(Tb200)和持续时间(T200)。结果:肺动脉主干到达峰值的时间,B组明显早于A组、强化峰值,B组明显高于A组,且均有显著性差异;T200及Tb200,两组间也存在显著性差异。结论:在多层螺旋CT肺动脉成像检查中,使用高浓度、低剂量对比剂可以满足临床需要。 Objective:To study the feasibility of multislice CT angiography of pulmonary artery with high concentration and low dose contrast media.Methods:Forty patients with chest dynamic enhanced using multislice CT body-perfusion protocol were divided into 2 groups according to the kind and dosage of contrast media as follows: Group A,300 mgI/ml contrast media 100 ml and saline 30 ml;Group B,400 mgI/ml contrast media 60 ml and saline 30 ml.Injected rate was 4 ml/s.The time-density curve(TDC) of the trunk of pulmonary artery was delineated.The time to peak,peak contrast enhancement,the time of begin to 200 HU(Tb200) and the time of duration on 200HU(T200) were recorded.Results:As for the time to peak and peak contrast enhancement of the trunk of pulmonary artery,group B was earlier and higher than group A.The T200 and Tb200 had significant difference between the two groups.Conclusion:It is feasible to use high concentration and low dose contrast media for multislice CT pulmonary artery angiography.
出处 《医学影像学杂志》 2008年第3期265-267,共3页 Journal of Medical Imaging
关键词 肺动脉 对比剂 体层摄影术 X线计算机 Pulmonary artery Angiography Tomography,X-ray computed
  • 相关文献

参考文献8

  • 1Temy-Jardin M,Remy J.Spiral CT angiography of the pulmonary circulation[J]. Radiology, 1999,212:615 - 636.
  • 2Hopper KD, Mosher TJ, Kasales C.J, et al. Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector[J]. Radiology, 1997,205:269 - 271.
  • 3Haage P, Schmitz-Rode T, Huhner D, et al. Reduction of contrast material dose and artifacts by a saline flush using a double-power injector in helical CT of the thorax[J]. AJR, 2000,174:1049- 1053.
  • 4Kim T, Murakami T, Takahashi S, et al. Effect of injection rates contrast material on arterial phase hepatic CT [ J ]. AIR Am J Roentgenol, 1998,171:429 - 432.
  • 5Mitsuzaki K,Yamashita Y, Ogata I, et al. Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis contrast-injection protocol and optimal timing[J]. AJR, 1996, 167:753 - 757.
  • 6Yamashita Y, Komohara Y, Takahashim, et al. Abdominal helical CT: evalualion of optimal doses of intravenous contrast material-a prospective randomized study[J]. Radology,2000,216:718 -723.
  • 7Awai K, Hiraishi K, Hori S, et al . Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight[J]. Radiology, 2004, 230:142-150.
  • 8章作铨,张皓,高洁冰,秦培鑫,韩铭钧,刘小彬,何燕丽,钟国梅.MSCT肺动脉成像中对比剂优化剂量的初步研究[J].广东医学,2006,27(5):632-634. 被引量:11

二级参考文献10

  • 1REMY - JARDIN M, REMY J, ARTAUD D, et al. Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol[J]. Radiology, 1997, 204:157 - 163.
  • 2RUBIN G D. Three - dimensional spiral CT angiography of the aorta and its branches[M]//FISHMAN E K, JEFFREY R B J. Spiral CT.2nd ed. Philadelphia, Pa: Lippincott- Raven, 1998:361-402.
  • 3REMY- JARDIN M, REMY J. Spiral CT angiography of the pulmonary circulation[J]. Radiology, 1999,212(3): 615 - 636.
  • 4REMY- JARDIN M. Spiral CT of the chest[J]. Springer Verlag Inc,2001,58 - 68.
  • 5MITSUZAKI K, YAMASHITA Y, OGATA I, et al. Multiple - phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast- injection protocol and optimal timing[J]. AJR Am J Roentgenol, 1996,167:753 - 757.
  • 6KIM T, MURAKAMI T, TAKAHASHI S, et al. Effect of injection rates of contrast material on arterial phase hepatic CT[J]. AJR Am J Roentgenol, 1998,171(2):429 - 432.
  • 7YAMASHITA Y, KOMOHARA Y, TAKAHASHI M, et al. Abdominal helical CT: evaluation of optimal doses of intravenous contrast material-a prospective randomized study[J]. Radiology, 2000,216:718-723.
  • 8AWAI K, HIRAISHI K ,HORI S, et al. Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight[J]. Radiology,2004,230:142 - 150.
  • 9BAE K T.Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model[J].Radiology,2003 227:809-816.
  • 10ALTMAN P L, DITTMER D S. Respiration and circulation [M].Bethesda, Md: Fed Am SocExpBiol, 1971.