摘要 目的:探讨将改良妇科诊断治疗自控显示仪应用于数字X线机下,取代人工自动推注造影剂行子宫输卵管造影的可行性。方法:观察360例不孕不育妇女在数字X线机下,应用改良妇科诊断治疗自控显示仪自动推注造影剂行子宫输卵管造影结果。结果:360例全部取得满意的实时图象,其中子宫输卵管正常38例(10.56%),异常322例(89·44%)。结论:改良妇科诊断治疗自控显示仪应用于数字X线机下,取代人工自动推注造影剂行子宫输卵管造影,具有操作简单,安全可行,可避免操作者直接暴露于X线下等优点,值得临床应用。 Objective : To probe into the feasibility and security of using improved diagnosis and treatment equipment for gynecology in the hysterosalpingography, and compare the effect with the manual injection. Methods: 360 women with infertility were carried out hysterosalpingography with the improved diagnosis and treatment equipment for gynecology on X - ray digital radiography accompanied by the automatical injection of imaging reagents from August 2005 to August 2007, which was observed under the surveillance, and real - time images were collected. Results : All 360 cases were successfully obtained real - time images, and normal and abnormal uterus and fallopian tube were 38 cases ( 10. 56 % ) and 322 eases (89.44 % ), respectively. Conclusion: The improved diagnosis and treatment equipment for gynecology combined with X- ray digital radiography used in hysterosalpingography is simple, easy to manage and without exposure of radiation during the operation, which is worth being applied clinically.
出处 《中国计划生育学杂志》 北大核心 2008年第3期170-172,共3页 Chinese Journal of Family Planning
关键词 子宫输卵管造影 妇科诊断治疗自控显示仪 不孕不育 Hysterosalpingography Diagnosis and treat equipment for gynecology Infertile
  • 相关文献

参考文献1

二级参考文献2

共引文献2

同被引文献55

引证文献7

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部