期刊文献+

三峡电站结构混凝土配合比试验研究

Mix proportion experiment of the structure concrete as to the workshop of the Water Power Station of Three-Gorge Project
下载PDF
导出
摘要 长江三峡水利枢纽三期工程右岸电站厂房标段(TGP/CI-3)混凝土配合比试验,针对砂率、ZB-1A掺量、粉煤灰掺量以及水灰比等参数进行优化试验,分析了各参数对混凝土性能的影响,在满足规范要求的范围内对有关参数进行合理选择。 Firstly aims to carry the experiment of concrete mix proportion of the section of TGP/CI-3 as to the third phrase of the electric power station on the right bank of Three Gorge Project.Secondly,based on experiments,better the parameters such as the sand ratio proportion of ZB-1 A, the proportion of pulverized coal ash,water cement ratio and so on.Analyze the effect on the concrete performance.Lastly, satisfies with the standards, select the design parameters in reason.
出处 《混凝土》 CAS CSCD 北大核心 2008年第3期94-97,共4页 Concrete
关键词 长江三峡 混凝土 水电站厂房 配合比试验 Three Gorge Project concrete workshop of water power station mix proportion experiment
  • 相关文献

参考文献4

  • 1中华人民共和国国家经济贸易委员会.DL/T 5144-2001,水工混凝土施工规范[S].北京:中国电力出版社,2000.
  • 2DL/T 5150-2001,水工混凝土试验规程[S].北京:中国电力出版社,2000.
  • 3张应力.现代混凝土配合比设计手册[M].北京:人民交通出版社,2002.
  • 4栾军.现代试验设计优化方法[M].上海:上海交通大学出版社,1994.