期刊文献+

嵌体冠修复磨牙残冠的临床研究 被引量:8

Clinical Study of Restoration of Partial Molar Using Inlay Crown
下载PDF
导出
摘要 目的探讨和研究固位力欠佳的磨牙残冠的临床修复方法及效果。方法用金刚砂车针对患牙作常规的牙体预备,牙冠外形按全冠进行牙体预备,髓室部分制作箱状固位形,取印模、灌制模型,完成铸造嵌体冠,临床试戴、调改、黏结。结果经过2~5年随访观察,122颗患牙经过修复治疗后获得满意效果,个别患牙出现修复体食物嵌塞、牙龈炎症、颈缘密合不良。结论利用髓室固位的铸造金属嵌体冠对于治疗磨牙残冠是一种简单易行、效果良好的修复方法,严格的选择适应证以及准确的牙体预备和精确的加工制作是修复成功的前提和关键。 Objective Lack of stabilization is always a problem for partial crown restoration. This study was to find the optimal clinical techniques to restore partial crown at molar areas. Methods Using diamond bur, all partial crowns were prepared according to traditional technique. The shapes of crowns were prepared as same as full crowns. The pulp wails were prepared as a box stabilization shape. After that, the following procedures would be preformed: impression, make a model, fabricate an inlay, clinical tried, modification, and cement. Results Following up 2 -5 years, 122 teeth were archived satisfactory results. Only few cases had problems such as food impaction, gingival inflammation, and gingival margin open. Conclusion For partial molar restoration, casting inlay with pulp wall stabilization is easy and simple technique. Clinical restoration result was satisfactory. The keys for success are carefully selection of indications, preparation tooth and fabrication of inlay with accuracy.
出处 《广东牙病防治》 2008年第3期113-115,共3页 Journal of Dental Prevention and Treatment
关键词 嵌体 冠修复 磨牙残冠 髓室固位 Inlay Restoration Partial crowns Pulp wall stabilization
  • 相关文献

参考文献6

二级参考文献33

  • 1梁钦业,赵玮,赵云凤,李哲.镍铬钛合金铸造全冠适合性的研究[J].四川大学学报(自然科学版),2001,38(S1):126-129. 被引量:3
  • 2刘洪臣.利用各类变异固位体的各类变异固定桥的应用[J].口腔医学纵横,1995,:134-136.
  • 3湖北医学院主编.口腔解剖生理学.北京.人民卫生出版社,1980.151.
  • 4Bindl A, Mormann W. Marginal and internal fit of allceramic CAD/CAM crown copings on chamfer preparations[J]. J Oral Rehabil, 2005, 32:441-447
  • 5Oden A, Andersson M, Krystek-Ondracek L, et al.Five-year clinical evaluation of Procera AllCeram crowns[J].J Prosthet Dent, 1998, 80:450-456
  • 6Besimo C, Jeger C, Guggenheim R. Marginal adaption of titanium frameworks produced by CAD/CAM techniques[J].Int J Prosthodont, 1997, 10:541-546
  • 7May KB, Russell MM, Razoog ME, et al. Precision of fit: The Procera AllCeram crown[J]. J Prosthet Dent, 1998, 80:374-404
  • 8Bindl A, Mormann W. Clinical and SEM evaluation of an-ceramic chair-side CAD/CAM -generated partial crowns[J]. Eur J Oral Sci, 2003, 111 : 163-169
  • 9Martin N, Jedynakiewicz NM. Interface dimensions of CEREC-2 MOD inlays[J]. Dent Mater, 2000, 16: 68-74
  • 10Kelly JR, Davis SH, Campbeu SD. Nondestructive,three-dimensional internal fit mapping of fixed prostheses[J]. J Prosthet Dent, 1989, 61:368-373

共引文献51

同被引文献39

引证文献8

二级引证文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部