期刊文献+

铸造不锈钢桩核冠的临床应用 被引量:1

The application of Post-and-Core Crown
下载PDF
导出
摘要 目的研究铸造不锈钢桩核冠的临床修复效果。方法随机选择70例不同牙齿的残冠、残根,经完善根管治疗后行铸造不锈钢桩核冠加烤瓷牙修复,并与30例用预成桩加烤瓷牙修复牙齿进行对比。结果经半年至二年的随访观察,铸造不锈钢桩核冠成功率97.15%,预成桩成功率86.67%,两组相比差异有显著性(x2=4.08648,P<0.05)。结论铸造不锈钢桩核冠加烤瓷牙修复义齿优于预成桩。 Objective To observe the effectiveness of Post-and-Core Crown. Methods After root canal treatment, 70 cases of Post-and-Core Crown and 30 cases of prefabricated post was compared. Results Afater observation for 6424 month, The successful ratie of Post-and -Core Crown is 97.15%, The successful ratie of prefabricated post is 86.67%. there was sigrificant difference between the two groups (x^2=4.08648, p〈0.05). Conclusions The Post-and -Core Crown is especially satisfactory and better than the prefabricated post.
出处 《海南医学》 CAS 2008年第4期73-73,42,共2页 Hainan Medical Journal
关键词 铸造不锈钢桩核冠 预成桩烤瓷牙 根折 桩折 Post-and-Core Crown Prefabricatedpost Fracture of root Fracture of Post
  • 相关文献

参考文献3

二级参考文献11

  • 1黄辉.[D].西安:第四军医大学,1996,5.
  • 2[1]Christel P,Meunier A, Mechanical properties and short term in-vivo evaluation of yurium oxid-parially stabilized zirconia. J Biomed Mater Res,1989,23:45
  • 3[2]Rosentriu M,Comparision of in vitro fracture strength of metallic and tooth colored posts and cores. J Oral Rehabil,2000,27:595
  • 4Felton DA,Webb E L, Kanoy B E, et al. Thread endodontic dowels:Effect of postdesign on incidence of root fracture. J Prosthet Dent, 1991,65(2): 179.
  • 5Zillich R M,Corocran JF. Average maximun post lengths in endodontically treated teeth. J Prosthet Dent, 1984,52 (4) :489.
  • 6Pameijer CH, Stanley HR, Ecker G. In vitro retention of three self-tapping post and core systems. J Dent Res, 1991,70(Spec Iss) :973(abstract).
  • 7Millstein PL, Ho J ,Nathanson D. Retention between a serrated steel dowel and different core materials. J Prosthet Dent,1991,65(4) :480.
  • 8Goldman M,Vitre RD, Pier M. Effect of the dentin smeared layer on tensile strength of cemented posts. J Prosthet Dent,1984,52(4):485.
  • 9Standlee J P, Caputo AA, Hanson E C. Retention of endodontic dowels : Effects of cement, dowel length, diameter, and design. J Prosthet Dent, 1978,39(4) :400.
  • 10Johnson J K, Sakumura J S. Dowel form and tensile force. J Prosthet Dent, 1978,40(6) : 645.

共引文献20

同被引文献9

  • 1谢立莉,彭利辉.磨牙残根残冠分根保存修复的临床应用[J].海南医学,2006,17(11):59-60. 被引量:1
  • 2Zyskind K,Zyskind D,Soskolne WA,et al.Orthodontic forced eruption:case report of an alternative treatment for subgingivally fractured young permanent incisors[J].Quintessence Int,1992,23:393-399.
  • 3Anthony G,Gegauff.Effect of crown lengthening and ferrule placement on static load failure of cemented cast post-cores and crowns[J].The Journal of Prosthetic Dentistry,2000,84(2):169-179.
  • 4Lanning SK,Waldrop TC,Gunsolley JC,et al.Surgical crown lengthening:evaluation of the biological width[J].Periodontology,2003,74(4):468.
  • 5Goracci C,Grandini S,Bossu M,et al.Laboratory assessment of the retentive potential of adhesive posts:A review[J].Journal of Dentistry,2007,35(11):827-835.
  • 6Hayashi M.,Takabashi Y.,Imazato S.,et al.Fracture resistance of pulpless teeth restored with post-cores and crowns[J].Dent Material,2006,32:477-485.
  • 7Smith CT,Schuman NJ,Wasson W.Biomechanical criteria for evaluating prefabricated post-and-core systems:a guide for the restorative dentist[J].Quintessence Int,1998,29(5):305-312.
  • 8Peguretti A,Fambri L,Zappini G,et al.Finite element analysis of a glass fibre reinforced composite endedontic post[J].Biomaterials,2002,23(13):2667-2668.
  • 9孟庆飞,陈亚明,光寒冰.不同桩核和箍结构与牙根抗力的实验研究[J].现代口腔医学杂志,2007,21(5):520-522. 被引量:11

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部