期刊文献+

Fenton试剂处理电厂难降解离子交换树脂再生废水 被引量:1

Treatment of Regeneration Wastewater of Ion-exchange Resin in Electric Power Plant with Fenton Agent
下载PDF
导出
摘要 电厂离子交换树脂再生废水是电厂除盐工艺的水处理系统中产生的废水,均匀混合后CODCr可达300~450mg/L,BOD5/COD<0.1,生化性能很差,采用生物法处理无法达标。文章研究了采用Fenton试剂处理电厂难降解离子交换树脂再生废水的可行性,并采用单因素法得出处理最佳条件:pH=3.0~3.5;H2O2/FeSO4·7H2O(摩尔比)为36∶1;反应时间≥2h。 Regeneration wastewater of ion-exchange resin is caused by the softening processing in the electric plant. After even mixture, the biodegradable performance is worse, the CODCr is about 300-450 mg/L, BOD5/CODCr less than 0.1, which can not be treated by the biological process. Feasibility of Fenton agent used to treat the recalcitrant regeneration wastewater of ion-exchange resin in electric power plant is studied, the optimum operation conditions are obtained: pH=3.0-3.5, the ratio of H2O2/(FeSO4·7H2O)(mol/mol)=36:1, reaction time≥ 2 h.
出处 《苏州科技学院学报(工程技术版)》 CAS 2008年第1期18-22,共5页 Journal of Suzhou University of Science and Technology (Engineering and Technology)
基金 上海市高等学校青年科学基金项目(2000QN58)
关键词 催化氧化 FENTON试剂 难生物降解废水 catalytic oxidation Fenton agent recalcitrant wastewater
  • 相关文献

参考文献5

  • 1[1]Joseph J Pignatello,Esther Oliveros,Allison Mackay,et al.Advanced oxidation processes for organic contaminant destruction based on the Fenton reaction and related chemistry[J].Environmental Science & Technology,2006,36(1):1-84.
  • 2[2]Browers A R,P Gaddipati.Treatment of toxic or refractory wastewater with hydrogen peroxide[J].Wat.Sci.Technol,1989,21:477-486.
  • 3王罗春,闻人勤,丁桓如.Fenton试剂处理难降解有机废水及其应用[J].环境保护科学,2001,27(3):11-14. 被引量:147
  • 4范拴喜,江元汝.Fenton法的研究现状与进展[J].现代化工,2007,27(z1):104-107. 被引量:47
  • 5[6]Bishop D F,Stern G.Hydrogen peroxide catalytic oxidation of refractory organics in municipal waste water[M].I & EC Process Design and Development,1968,7(1):110-117.