期刊文献+

基于微透镜阵列的重金属离子阵列传感器研究 被引量:1

Investigation of light addressable potentiometric sensor array senstive to heavy metal ion based on micro-lens array
下载PDF
导出
摘要 研制了一种基于微透镜阵列的光寻址电位阵列传感器,用以实现同一溶液中多种重金属离子的同时检测.采用脉冲激光沉积(PLD)技术在LAPS上制备Cu^2+、Cr^6+、Pb^2+、Fe^3+4种重金属离子的敏感薄膜,并利用微透镜阵列把单束激光转化成激光点阵作为LAPS阵列的光源,从而得到4×4的重金属离子敏感LAPS阵列,实现了对这4种重金属离子的检测.实验结果表明,LAPS阵列传感器能够同时检测浓度为10^-5~10^-3mol/L的以上4种金属离子混合溶液. A light addressable potentiometric array sensor was designed to realize the simultaneous detection of multi-heavy metal ions in the same solution. The pulsed laser deposition(PLD)technique was used to prepare the thin film sensitive to Cu^2+ , Cr^6+ , Pb^2+ , Fe^3+ on the LAPS unit, and the micro-lens array was used to transfer the single laser beam to laser light array in this 4×4 LAPS array sensor sensitive to heavy metal ion. Based on four kinds of heavy metal ions in the same solution were detected. The experimental result indicated that the array can detect the solution containing Cu^2+ , Cr^6+ , Pb^2+ , Fe^3+ whose concentration is 10^-5-10^-3 mol/L.
出处 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2008年第3期517-521,共5页 Journal of Zhejiang University:Engineering Science
基金 国家“863”高技术研究发展计划资助项目(2001AA635060) 浙江省国际合作重点资助项目(2004C24002)
关键词 重金属离子检测 光寻址电位阵列传感器 微透镜阵列 detection of heavy metal ion light addressable potentiometric array sensor micro-lens array
  • 相关文献

参考文献10

  • 1HAFEMAN D G, WALLACE J P, MCCONNELL H M. Light-addressable potentiometric sensor for biochemical systems[J]. Science, 1988, 240: 1182- 1185.
  • 2MOURZINA Y G, SCHOING M J, SCHUBERT J, et al. A new thin-film Pb microsensor based on chalcogenide glass [J]. Sensors and Actuators B, 2000 (71) : 13 - 18.
  • 3SCHUBERT J, SCHOING M J, MOURZINA Y G, et al. Multicomponent thin film for electrochemical sensor applications prepared by pulsed laser depositon [J]. Sensors and Actuators B, 2001 ( 76 ) : 327 - 330.
  • 4门洪,邹绍芳,Andrey Legin,王平.一种新型汞离子选择薄膜传感器[J].分析化学,2005,33(3):428-431. 被引量:5
  • 5MEN Hong, ZOU Shao-fang, LI Yi, et al. A Novel electronic tongue combined MLAPS with stripping voltammetry for environmental detection [J]. Sensors and Actuators B, 2005(110) :350 - 357.
  • 6门洪,邹绍芳,王平,Andrey Legin,沈静琴,许祝安.脉冲激光沉积技术制备的薄膜传感器的研究[J].浙江大学学报(工学版),2005,39(4):600-604. 被引量:3
  • 7ZHANG Qin-tao, WANG Ping, WOLFGANG J P, et al. A novel design of multi-light LAPS based on digital compensation of frequency domain[J]. Sensors and Actuators B ,2001(73) :52 - 156.
  • 8韩泾鸿,梁卫国,张虹,陈德勇,徐磊.微阵列光寻址生化传感器系统性能研究[J].电子与信息学报,2003,25(6):831-837. 被引量:6
  • 9陈祥献,杨国光,陈洪谬,侯西云,许乔.微透镜阵列的加工技术研究[J].浙江大学学报(自然科学版),1998,32(3):286-291. 被引量:6
  • 10NEMEC P, FRUMAR M, JEDELSKY J, et al. Thin amorphous chalcogenide films prepared by pulsed laser deposition [J]. Journal of Non-Crystalline Solids, 2002 (299-302) : 1013 - 1017.

二级参考文献23

  • 1D.G.Hafeman,J.W.Parce,H.M.McConnell,Light-addressable potentiometric sensor for biochemical system,Science,1988,240,1182—1185.
  • 2M. Sartore, M. Adami, C. Nicolini, Computer simulation and optimization of a light addressable potentiometric sensor, Biosensors & Bioeletronics 1992, 8(7), 57-64.
  • 3M. Sarore, M. Adami, C. Nicolini, L. Bousse, S. Mostarshed, D. Hafeman, Minority carrier diffusion length effects on light-addressable potentiometric sensor (LAPS) devices, Sensors and Actuators A, 1992, (32), 431-436.
  • 4L. Bousse, S Mostarshed, D. Hafeman, M. Sarore, M. Adami, C. Nicolini, Investigation of carrier transport through silicon wafers by photocurrent measurements, J. Appl. Phys., 1994, 75(8),4000-4008.
  • 5Liang Weiguo, Han Jinghong, Zhang Hong and Chen Deyong, A Light Addressable Potentiomctric with an Array of Sensing Regions, Proc. SPIE, 2001, 4414, 386-388.
  • 6许乔,光学学报,1996年,16卷,9期
  • 7许乔,仪器仪表学报,1996年,17卷,增刊
  • 8叶雄英,仪器仪表学报,1996年,17卷,增刊
  • 9汤一新,仪器仪表学报,1995年,16卷,1期
  • 10Sch(o)ning M J, Mourzina Yu G, Schubert J, Zander W, Legin A, Vlasov Yu G, Lüth H. Sensors and Actuators B, 2001, (78): 273~278.

共引文献15

同被引文献50

  • 1窦任生,林海,胡继承.控制液晶器件产生的程控透镜和微透镜阵列[J].光学学报,2005,25(7):959-964. 被引量:8
  • 2黄鹰,向思桦,陈四海,赖建军,易新建.微型光扫描器研究[J].红外与毫米波学报,2007,26(1):26-29. 被引量:5
  • 3Berreman D. Variable focus liquid crystal lens system: US 4190330[P]. 1980-02-26.
  • 4Sato S. Liquid crystal lens cell with variable focal length[J]. Jpn J Appl Phys.1979,18(9):1679-1684.
  • 5Chang M. Total internal reflection lens [J]. Appl Opt, 1985, 24(9) : 1256-1259.
  • 6Shibaguchi T, Funato H. Lead-lanthanum zirconate-titanate (PLZT) electro optic variable focal lengths lens with stripe eleclrodes[J]. Jpn J Appl Phys,1992,31(9B): 3196-3140.
  • 7Zhao L P, Bai N, Li X. et al. Efficient implementation of a spatial light modulator as a diffractive optical microlens array ina difital Hartmann wavefront sensor[J]. Appl Opt, 2006, 45(1):90-94.
  • 8Ren H, Fan Y H. Gauza S, et al. Tunable microlens arrays using polymer network liquid crystal[J]. Opt Commun,2004, 230(4/6) : 267.
  • 9Millan M S.Otno J. Cabr E P. Dynamic compensation of chromatic aberration in a programmable diffractive lens [J]. Opt Express,2006, 14(20) :9013-9112.
  • 10Millan M S, Oton J, Cabre E P. Chromatic compensation of programmable Fresnel lenses[J]. Opt Express.2006,14(13) : 6226-6242.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部