摘要 建立动物肝脏中常见的10种磺胺类药物(磺胺胍、磺胺嘧啶、磺胺二甲嘧啶、磺胺甲氧哒嗪、磺胺间甲氧嘧啶、磺胺-5-甲氧嘧啶、磺胺氯哒嗪、磺胺甲恶唑、磺胺二甲氧嘧啶、磺胺喹恶啉)残留量液相色谱同时测定方法。样品通过溶剂提取净化、荧光胺柱前衍生化,用配有荧光检测器的高效液相色谱仪测定,外标法定量。其线性范围分别为2~200μg/L、4~400μg/L、10~1000μg/L,线性相关系数r>0.999;方法检出限(LOD)为2~10μg/kg;其中9种磺胺,在5~100μg/kg的3个添加水平范围内的平均回收率为70.6%~90.2%;相对标准偏差为4.1%~7.6%。 A HPLC method has been established for determination of 10 sulfonamide drug residues in animal liver, including sulfaguanidine monohydrate, sulfadiazine, sulfadimidine, sulfamethoxypyridazine, sulfamonomethoxine, sulfamethoxydiazine, sulfachloropyridazine, sulfamethoxazole, sulfadimoxinum, sulfaquinoxaline. The sample was treated with solvent extraction and pre-column derivatization with fluorescamine, then detected by HPLC-fluorescence detector. The quantitative method was external standard method. The linear ranges of 10 sulfonamides are 2 200μg/L,4-400μg/L, 10 - 1000μg/L, and the linear correlation coefficient r 〉0. 999. The limits of detection (LOD) for the method are 2 - 10μg/kg. In the ranges of 5 - 100μg/kg for 9 sulfonamides ,the average recoveries are 70. 6% - 90.2%, the relative standard deviations are 4. 1% -7.6%.
出处 《现代仪器》 2008年第2期21-23,共3页 Modern Instruments
关键词 磺胺 动物肝脏 荧光胺 衍生化 高效液相色谱-荧光检测器 Sulfonamides Animal liver Fluorescamine Derivatization HPLC-fluorescence detector
  • 相关文献

参考文献4

  • 1中华人民共和国国家标准GB/T20759-2006畜禽肉中十六种磺胺类药物残留量的测定液相色谱-串联质谱法
  • 2中华人民共和国国家标准GB/T18932.5-2002蜂蜜中磺胺醋酰、磺胺吡啶、磺胺甲基嘧啶、磺胺甲氧哒嗪、磺胺对甲氧嘧啶、磺胺氯哒嗪、磺胺甲基异恶唑、磺胺二甲氧嘧啶残留量的测定方法液相色谱法
  • 3Craig D. C. S, Jason C. S, Roger M. J. AOAC Int, 2004,87 (5): 1264 - 1268
  • 4Pang Guofang, Cao Yanzhong, Zhang Jinjie ,Jia et al. Journal of Analytical Chemistry 2005,33(9): 1252 - 1256

共引文献1

同被引文献136

引证文献8

二级引证文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部