两种锚固碳纤维布方法对比试验研究

Two Anchorage Methods Experimental Research on Carbon Fiber Sheets
下载PDF
导出
摘要 碳纤维布加固混凝土梁负弯矩区常用的机械锚固法是角钢压条锚固法,但有限元分析结果表明柱侧钢板的限制使得角钢底板与梁顶变形不协调。试验结果验证了有限元分析的结论,并证明钢板压条锚固法可以有效锚固碳纤维布。锚固效果较好时,试件的"刚域"长度较大,且"刚域"长度的延伸对锚固效果的发挥有较大作用。 When negative moment section of beams are strengthened by using carbon fiber sheets, angle iron hold - down strip is a common mechanism anchorage method. But finite element analysis conclusion shows that the steel slab on the column side will restrict angle iron soleplate harmonized with the deformation of the beam. Experimental results demonstrated the conclusion of finite element analysis and proven that steel slab holddown strip could anchor carbon fiber sheets effectively. When anchoring effect was better, stiff field of the test sample was longer and the extension of stiff field length would play an important role to anchoring effect.
出处 《结构工程师》 2008年第1期77-81,共5页 Structural Engineers
关键词 碳纤维布 加固 梁负弯矩区 机械锚固方法 carbon fiber sheet, strengthening, negative moment section of beam, mechanism anchorage method
  • 相关文献

参考文献4

二级参考文献6

  • 1吴智深.复合材料在基础工程设施的增强和加固方面的现状与发展.见:中国纤维增强塑料(FRP)混凝土结构学术交流会论文集,2000.
  • 2日織コンポジツト株式會社.連續織維シ-トにょるコンクリ-ト構造物補修·補强工法技術資料.1999.
  • 3Guidelines for the selection,clesign and installation of fiber reinforced polymer (FRP) systems for externally strengthening concrete structures. Reported hy ACI ,committee 440,1999.
  • 4Zhishen Wu, Hedong Niu. Shear transfer along frp-concrete interface in flexural members. J. Materials. Conc. Struct., Pavements, JSCE,No. 662/V-49,2000, November: 231-245.
  • 5碳纤维片材加固修复混凝土结构技术规程(报批稿).2001.
  • 6叶列平,崔卫,岳清瑞,胡孔国.碳纤维布加固混凝土构件正截面受弯承载力分析[J].建筑结构,2001,31(3):3-5. 被引量:134

共引文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部