加氢反应器在壁温超高条件下运行的应力分析 被引量:1

Stress Analysis on Hydrogenation Reactor Under Overheating Wall Temperature
下载PDF
导出
摘要 冷壁加氢反应器的内保温由于施工质量、操作条件等因素的影响,常会发生失效等故障,导致反应器局部温度超高。由于温差应力的存在,局部壁温超温非常不利于装置的安全运行。研究了反应器在轴向和周向上的温差应力分析与计算问题,提出超温部位为正方形、圆形、圆环、椭圆等的应力分析计算方法,供冷壁反应器使用单位参考。 Internal thermal of cold wall hydrogenation reactor often may become invalidation as a result of factors such as construction quality and working conditions. It leads to the reactor partially temperature extremely high. Because of the existence of thermal stress, overheating partial wall temperature is extremely disadvantageous to the equipment safe operation. The reactor in axial and circumferential thermal stress analysis and the calculation problem were studied. The stress analysis and computational method were put forward when ultra-- warm spot is the square, the circular, the ring, the ellipse etc.
出处 《辽宁石油化工大学学报》 CAS 2008年第1期37-40,共4页 Journal of Liaoning Petrochemical University
关键词 加氢反应器 温差应力 应力分析 Hydrogenation reactor Thermal stress Stress analysis