期刊文献+

一种改进的自适应形变模型及其血管内超声图像边缘提取应用 被引量:5

An Improved Topologically Adaptable Snakes and the Applications in Edge Detection of IVUS Images
下载PDF
导出
摘要 血管内超声(IVUS)图像冠状动脉血管壁内膜的边缘提取对冠状动脉疾病的诊断和治疗有着重要意义。提出一种改进的自适应形变模型(T-Snake),该模型能够解决基本T-Snake模型中的自交(Self-collisions)问题,并有着更高的数值计算精度。同时,基于改进的T-Snake模型,给出一种用于自动提取IVUS序列图像冠状动脉血管壁内膜边缘的方法。实验结果表明,所提出方法准确性和可靠性较高,对IVUS序列图像处理的可重复性和鲁棒性较好;表明了改进T-Snake模型的有效性和可实现性。 The edge detection of intravascular ultrasound (IVUS) images is important in the diagnosis and treatment of the coronary artery disease. An improved topologically adaptable snakes (T-Snake) was proposed in the paper, which could avoid the self-collisions of the T-Snake and had the advantage of higher numerical precision. A method based on the improved T-Snake to automatically detect the intima edge of IVUS image was also proposed. Experiments showed that the method was accurate, reproducible and robust for sequential IVUS frames. The improved T-Snake was effective and realizable as well.
出处 《中国生物医学工程学报》 CAS CSCD 北大核心 2008年第2期276-281,共6页 Chinese Journal of Biomedical Engineering
基金 国家自然科学基金资助项目(60571040) 山东省优秀中青年科学家科研奖励基金项目(2005BS01006)
关键词 自适应形变模型 血管内超声图像 边缘提取 法线矢量 topolog/cally adaptable snakes intravascular ultrasound edge detection: normal vector
  • 相关文献

参考文献18

  • 1Sonka M, Zhang Xiangmin, Siebes M, et al. Segmentation of intravascular ultrasound images : a knowledge-based approach [J]. IEEE Trams Medical Imaging. 1995, 14(4) : 719 - 732.
  • 2Zhang Xiangmin, McKay CR, Sonka M. Tissue characterization in intravascular ultrasound images [J]. IEEE Trans Medical Imaging. 1998, 17(6) : 889 - 899.
  • 3Brusseau E, Korte CL, Mastik F, et al. Fully automatic luminal contour segmentation in intracoronary ultrasound imaging-A statistical approach [ J]. IEEE Trails Medical Imaging. 2004, 23 (5): 554 - 566.
  • 4Gil D, Radeva P, Saludes J, et al. Automatic segmentation of artery wall in coronary IVUS images : A probabilistic approach [ A ]. In: Murray A, eds. Computers in Cardiology 2000 [ C ]. Cambridge, Massachusetts: IEEE Computer Society, 2000. 4352- 4355.
  • 5Zhu Hui, Liang Yun, Friedman M. IVUS image segmentation based on contrast [ A ]. In: Sonka M, Fitzpatrick J, eds. Proceedings of SPIE [C]. Bellingham, Wash: SPIE, 2002. 1727- 1733
  • 6曲怀敬,孙丰荣,李艳玲,刘泽,宫延新,张梅.基于活动轮廓模型和统计特征的血管内超声图像的边缘提取[J].中国图象图形学报,2005,10(8):999-1004. 被引量:10
  • 7Plissiti ME, Fotiadis DI, Michalis LK, et al. An automated method for lumen and media-adventitia border detection in a sequence of IVUS frames [ J ]. IEEE Trans Information Technology in Biomedicine. 2004, 8(2) : 131 - 141.
  • 8Fan Liexiang, Herrington DM, Santago P, 3D ultrasound image segmentation using multiple incomplete features sets [ A]. In: Hanson K, eds, Proceedings of SPIE [C], Bellingham, Wash: SPIE, 1999. 948-956.
  • 9Kovalski G, Beyar R, Shofti R, et al. Three-dimensional automatic quantitative analysis of intravascular ultrasound images [ J ].Ultrasound in Med and Biol. 2000, 26(4) : 527 - 537.
  • 10Haas C, Ermert H, Holt S, et al. Segmentation of 3D intravascular ultrasonic images based on a random field model [J]. Ultrasound in Med and Biol. 2000, 26(2) : 297 - 306.

二级参考文献53

  • 1[1]M. Kass, A. Witkin, D. Terzopoulos, Snakes: active contour models, Int'l J. Comp. Vis., 1987,1(4), 321-331.
  • 2[2]A.A. Amini, T. E. Weymouth, R. C. Jain, Using dynamic programming for solving variational problems in vision, IEEE Trans. on Patt. Anal. Mach. Intell., 1990, 12(9), 855-867.
  • 3[3]L.D. Cohen, On active contour models and balloons, CVGIP: Imag. Under., 1991, 53(2), 211-218.
  • 4[4]T. McInerney, D. Terzopoulos, A dynamic finite element surface model for segmentation and tracking in multidimensional medical images with application to cardiac 4D image analysis, Comp.Med. Image Graph., 1995, 19(1), 69-83.
  • 5[5]V. Caselles, F. Catte, T. Coll, F. Dibos, A geometric model for active contours, Numerische Mathematik, 1993, 66, 1-31.
  • 6[6]R. Malladi, J. A. Sethian, B. C. Vemuri, Shape modeling with front propagation: a level set approach, IEEE Trans. on Patt. Anal. Mach. Intell., 1995, 17(2), 158-175.
  • 7[7]V. Caselles, R. Kimmel, G. Sapiro, Geodesic active contours, in Proc. 5th Int'l Conf. Comp.Vis., Cambridge, MA, 1995, 694-699.
  • 8[8]R.T. Whitaker, Volumetric deformable models: active blobs, Tech. Rep. ECRC-94-25, European Computer-Industry Research Center GmbH, 1994.
  • 9[9]G. Sapiro, A. Tannenbaum, Afline invariant scale-space, Int'l J. Comp. Vis., 1993, 11(1), 25-44.
  • 10[10]L.D. Cohen, On active contour models and balloons, CVGIP: Imag. Under., 1991, 53(2), 211-218.

共引文献35

同被引文献75

引证文献5

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;