翻修贴片设备在ICCD光锥耦合中的应用 被引量:1

Rework placement system applied in ICCD fiber optic taper mounting procedure
下载PDF
导出
摘要 为了提高光锥耦合ICCD成像系统的成品率和成像质量,提出了一种将通用BGA翻修系统中的高精度贴片设备ERSA PL550A用于光锥和CCD耦合工艺的方法。利用光锥或光纤面板与CCD的耦合实例描述了这种技术方案的系统构成、操作流程和耦合精度,证明了它在简化耦合工艺、降低操作难度、控制耦合操作的重复性和提高生产效率方面具有良好的性能。对CCD玻璃窗的开启方法和光锥形状尺寸的二次修改也进行了简要说明。 In order to improve the qualified product ratio and image performance of fiber optic taper coupled ICCD,a general precision placement system ERSA PL550A is applied in the techniques of fiber optic taper coupled with CCD.The equipments system,mounting procedure and coupling accurate are described by the example.It is proved that this method can simplify the coupling procedure,make the operation easy,improve coupling job efficiency and uniformity of product.The method of how to remove the CCD glass window and how to shape the fiber optic taper are mentioned.
出处 《光学技术》 EI CAS CSCD 北大核心 2008年第2期241-243,共3页 Optical Technique
关键词 ICCD 光锥耦合 翻修设备 贴片设备 ICCD CCD fiber optic taper bonding rework system placement system
  • 相关文献

参考文献6

二级参考文献18

  • 1周正干,滕升华,江巍,安振刚.X射线平板探测器数字成像及其图像校准[J].北京航空航天大学学报,2004,30(8):698-701. 被引量:38
  • 2崔元源.光学纤维锥体图象传输元件的研制.第一届全国光子学学术会议论文摘要集[M].,1996.186.
  • 3[1]Beal G, Boucharlat G, Cappechi F. 512×512 CCD visible imager with a fiber optic faceplate. SPIE Solid State Imaging Arrays. 1985, 570.20~26.
  • 4[2]Roehrig H, Ovitt T W, Dallas W J, et al. Development of a high resolution X ray imaging device for use in coronary angiography. SPIE Medical Imaging. 1987, 767.144~153.
  • 5[3]Burger R J, Greenberg D A. Fiber array optics for electronic imaging. SPIE Electron Image Tubes and Image Intensifiers Ⅱ. 1991, 1449.174~185.
  • 6[4]Williams G M. A high performance LLLTY CCD camera for nighttime pilotage. SPIE Electron Tubes and Image Intensifiers. 1992, 1655.14~32.
  • 7[5]Dunham M E, Donaghue D W, Schempp W V, et al. Performance factors for intensified CCD systems. SPIE Electron Tubes and Image Intensifiers. 1992, 1655.66~73.
  • 8[6]Mara D O′, Phillips W, Stanton M, Saroff D. Design criteria and development of components for a modular CCD based detector for X ray crystallography. SPIE High Resolution Sensors and Hybrid Systems. 1992, 1656.450~456.
  • 9[7]Naday I, Ross S, Westbrook E M, Zentai G. Charge coupled device/fiberoptic taper array X ray detector for protein crys tallography. SPIE. 1997, 3019.17~34.
  • 10崔元源,第一届全国光子学学术会议论文摘要集,1996年,186页