摘要
提出几种计算和测量激光棒负透镜等效焦距的方法.估算了在单次泵浦情况下由于激光棒内温升不均匀造成的热透镜效应.用等效薄透镜方法计算了这两种透镜效应的综合效应.根据此种综合效应设计出不同的激光腔型和共振腔参数做激光实验,使激光效率提高3~5倍,发散度减小.
The authors have reported two methods for measuring the efficient focal distance of the laser rod lenses.The thermo lens effects of laser rod have been calculated too.Using effective thin lens method the comprehensive effects the two effects were calculated,and with these results aurhors have designed a new laser resonance cavity.With these new resonance cavity, the laser′s energy output of 3~5 times of those of normal cavities were obtained
出处
《四川大学学报(自然科学版)》
CAS
CSCD
北大核心
1997年第5期616-620,共5页
Journal of Sichuan University(Natural Science Edition)