摘要 提出一种用于电能质量研究的新型交流电弧炉混沌模型。首先,基于电弧炉负载U-i特性曲线的分段线性化,依据负载实际消耗的有功功率,得到能精确反映电弧炉稳态特性的静态模型,该模型适用于电弧炉引起的谐波问题研究。然后,用基于不对称非线性电阻蔡氏电路产生的低频混沌信号对静态电弧电压进行调制,模拟电弧炉运行的动态过程,得到电弧炉负载的动态模型,该模型特别适用于研究电弧炉引起的电压波动与闪变问题。在Matlab下,对电弧炉静态、动态模型进行仿真研究。仿真结果与实际测量数据相比较,显示该模型能够精确描述电弧炉引起的谐波和电压波动等电能质量问题。模型有效且易于使用,它的提出为电能质量治理措施研究奠定了基础。 A novel chaotic model of AC electric arc furnace is introduced, which is useful for power quality study. Firstly, based on a piece-wise linear approximation of U-i characteristic curve of electric arc furnace load, dependeding on the active power consumed by the load, the static model is developed, which can accurately represent the static behaviors of electric arc furnace. The static model is useful for harmonic study. Secondly, a low-frequency chaotic signal is generated via the Chua's circuit based on asymmetric nonlinear resistive element, using the chaotic signal to modulate the static voltage of electric arc, finally the dynamic model is developed, which can accurately simulate the dynamic behaviors of electric arc furnace. The dynamic model is useful for voltage fluctuation and flicker study. The static model and the dynamic model are simulated in Matlab. Comparing the simulated results with the measurement data, it is shown that the model can accurately represent the power quality problems, such as harmonic and voltage fluctuation. The developed model is valid and easy to use, which will promote the precaution measures study against power quality problems.
出处 《中国电机工程学报》 EI CSCD 北大核心 2008年第10期106-110,共5页 Proceedings of the CSEE
基金 国家重点基础研究发展计划项目(973项目)(2005CB221505) 博士点基金项目(20050248058)~~
关键词 电弧炉 电能质量 混沌 蔡氏电路 电压波动与闪变 谐波 负荷建模 electric arc furnace power quality chaos Chua's circuit voltage fluctuation and flicker harmonic load modeling
  • 相关文献

参考文献20

  • 1Manchur G, Erven C C. Development of a model for predicting flicker from electric arc furnaces[J]. IEEE Trans. on Power Delivery, 1992, 7(1): 416-426.
  • 2Rafel C B, Tomas G. Identification and modeling of a three phase arc furnace for voltage disturbance simulation[J]. IEEE Trans. on Power Delivery, 1997, 12(4): 1812-1817.
  • 3Montanari G C, Loggini M, Cavallini A, et al. Arc-furnace model for the study of flicker compensation in electrical networks[J]. IEEE Trans. on Power Delivery, 1994, 9(4). 2026-2033.
  • 4Varadan S, Makram E B, Girgis A A. A new time domain voltage source model for an arc furnace using EMTP[J]. IEEE Trans. on Power Delivery, 1996, 11(3). 1685-1691.
  • 5王晶,束洪春,林敏,陈学允.用于动态电能质量分析的交流电弧炉的建模与仿真[J].电工技术学报,2003,18(3):53-58. 被引量:32
  • 6Mayordomo J G, Beites L F, Asensi R, et al. A new frequency domain arc furnace model for iterative harmonic analysis[J]. IEEE Trans. on PowerDelive~, 1997, 12(4): 1771-1778.
  • 7祁碧茹,肖湘宁.用于电压波动研究的电弧炉的模型和仿真[J].电工技术学报,2000,15(3):31-35. 被引量:38
  • 8Anxo Prieto Alonso M, Donsion M P. An improved time domain arc furnace model for harmonic analysis[J]. IEEE Trans. on Power Delivery, 2004, 19(1): 367-373.
  • 9刘小河,赵刚,于娟娟.电弧炉非线性特性对供电网影响的仿真研究[J].中国电机工程学报,2004,24(6):30-34. 被引量:61