期刊文献+

纺锤体流量计的流场数值模拟 被引量:17

Numerical Simulation of the Flow Field in Spindle Flowmeter
下载PDF
导出
摘要 介绍了一种新型的节流式差压流量计——纺锤体流量计(又名槽道流量计)。数值模拟结果表明,在来流规则或畸变情况下纺锤体等直径段部分均能很好地形成环形槽道流动,使测量重复性和精确度得到大幅提高成为可能;同时,由于完全避免了流动分离,在高雷诺数下的压力损失与所得差压之比可小于孔板流量计的二分之一。实验结果验证了数值模拟的可靠性。 The spindle flowmeter (also named channel flowmeter), a new type of differential pressure flowmeter, is introduced. The results of numerical simulation indicate that an annular channel flow is formed in conditions of regular or aberrant coming stream, which makes it possible to improve the repeatability and precision of measurement. The ratio of pressure drop to differential pressure obtained from the spindle flowmeter could be 50% lower than that of the orifice flowmeter. The experiment results validate the reliability of the numerical simulation.
作者 钟伟 明晓
出处 《计量学报》 EI CSCD 北大核心 2007年第3期262-265,共4页 Acta Metrologica Sinica
关键词 计量学 纺锤体流量计 数值模拟 槽道流动 差压 压力损失 Metrelogy Spindle flowmeter Numerical simulation Channel flow Differential pressure Pressure drop
  • 相关文献

参考文献4

二级参考文献22

  • 1王伯年,余国和,陈中.割线法及其在确定差压式流量计参数中的应用[J].计量学报,1996,17(3):211-214. 被引量:3
  • 2Mills R D. Numerical solution of viscous flow through a pipe orifice at low Reynolds numbers [ J ]. Journal of Mechanical Engineering Science, 1968, 2: 133 ~ 140.
  • 3Meier H F, Alves J J N, Mori M. Comparison between staggered and collocated grids in the finite-volume method performance for single and multi-phase flows[J]. Computers and Chemical Engineering, 1999, 23: 247~ 262.
  • 4GB/T2624-93.流量测量节流装置用孔板、喷嘴和文丘里管测量充满圆管的流体流量.[S].,..
  • 5[美]RW米勒 孙延祚译.流量测量工程手册(第一版)[M].北京:机械工业出版社,1990..
  • 6GB/T18604-2001.用气体超声流量计测量天然气流量:中华人民共和国国家标准.[S].中华人民共和国国家质量监督检验检疫总局发布,2001-12-30发布,2002-08-01实施..
  • 7Measurement of Gas By Multipath Ultrasonic Meters Transmission Measurement committee Report No.9,June 1998
  • 8International Standard ISO 9951 First edition 1993-12-01:Measurement of Gas Flow in Closed conduits-Turbine Meters, Ref number:ISO 9951:1993(E)
  • 9Stewart D G,NEL et al. North Sea Flow Measurement Workshop. 22nd-25th Wet Gas Metering with V-cone Meters,Oct,2002
  • 10Steve Caldwell, Tom kegel, Peters R J W . Calib- ration of large High Pressure V-cone Flowmeter at High Reynolds Numbers in the CEESI Iowa Natural Gas Test Facility.FLOMEKO 2003 Paper Ref No 011(第6章第2篇文章)

共引文献80

同被引文献85

引证文献17

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部