摘要
提出了采用人工湿地处理洪湖蓝田生态园旅游区酒店污水的措施,并建立了示范工程。建成后,在日处理量为40m3/d的条件下,人工湿地对TN、TP和CODCr的去除率分别为81.39%、66.07%和53.66%。本工程经过4个月的正常运行,生态园酒店排出污水经过湿地处理后,水质有比较明显的改善。工程有机地将景观与人工湿地相结合,景观与当地旅游区特点相融合。
The paper presented the results of constucted wetland treating wastewater of the hotel in Honghu Lantian ecological tourist attraction. The multiple constructed wetland treatment removed major portions of total phosphorus,total nitrogen and CODCr constituents of the inflow (40m^3/d) with removal rates of 66.07%, 81.39% and 53.66%, respectively. After four-month operation of the multiple constructed wetland treatment system, the water quality was improved significantly. This project made scenery integrated with constructed wetland and feature of tourism in Honghu Lantian ecological tourist attraction.
出处
《科技创业月刊》
2008年第4期131-133,共3页
Journal of Entrepreneurship in Science & Technology
基金
湖北省科技攻关项目"湖北省湿地生态系统健康评价及湿地恢复技术研究"成果(项目编号:2006AA305A04)。
关键词
人工湿地
旅游
酒店污水处理
constructed wetland, tourism, wastewater treatment of hotel