期刊文献+

Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes
下载PDF
导出
摘要 Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-Sth terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory. Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-Sth terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory.
出处 《Chinese Physics Letters》 SCIE CAS CSCD 2008年第4期1309-1312,共4页 中国物理快报(英文版)
基金 Supported by the Key Project of National Natural Science Foundation of China under Grant No60438030, and the National Hi-Tech Research and Development Programme of China under Grant No 2006AA02Z4D2.
关键词 RETINAL IMAGE QUALITY DESIGN RETINAL IMAGE QUALITY DESIGN
  • 相关文献

参考文献11

  • 1Zhu Y, Gao Y F and Wan G M 2001 New Diagnostic Technique of Ophthalmology (Beijing: Science)
  • 2Atchison D A 1992 Appl. Opt. 31 3579
  • 3Morgan P B and Efron N 2006 Contact Lens and Anterior Eye 29 59
  • 4Chernyak D A and Campbell C E 2003 J. Opt. Soc. Am. A 20 2016
  • 5Liang J Z and Williams D R 1997 J. Opt. Soc. Am. A 14 2873
  • 6Guirao A, Porter J, Williams D R and Cox I G 2002 J. Opt. Soc. Am. A 19 1
  • 7Liang J Z, Williams D R and Miller D T 1997 J. Opt. Soc. Am. A 14 2884
  • 8Yoon G Y and Williams D R 2002 J. Opt. Boa Am. A 19 266
  • 9Bara S, Mancebo T and Moreno-Baxriuso E 2000 Appl. Opt. 39 3413
  • 10Wang Y, Wang Z Q, Guo H Q and Quan W 2005 Acta Opt. Sin. 25 1519