摘要
研究了用气敏电极测定焦化厂废水中氨的分析方法,对测定的线性范围、响应时间、回收率、干扰物质等作了理论探讨和大量试验。在pH为11.5~14.0时,线性范围为1.00×10-5mol/L~1.00×10-1mol/L,最低检出限为5.0×10-6mol/L,RSD不大于2.5%。
Analysis method of ammonia in coking wastewater by means of gas sensitive electrode was introduced in the paper and also were analysed the linear range,response time,reused ratio and interfering substance.When pH in the wastewater is around 11.5~14.0,the linear range amounts to (1.00×10 -5 -1.00×10 -1 )mol/L,the lowest detection is (5.0×10 -6 )mol/L,RSD is ≤2.5%.
基金
冶金工业部教育司科学基金
关键词
气敏电极
氨
废水处理
焦化厂
gas sensitive electrode
ammonia
coking wastewater