期刊文献+

体外与非体外循环冠脉搭桥术后心肌损伤标志物水平变化 被引量:3

Changes of Myocardiac Injury Markers between Conventional on-pump Coronary Artery Bypass Grafting and off-pump Coronary Artery Bypass Grafting
下载PDF
导出
摘要 目的比较常规体外循环冠状动脉搭桥术和非体外循环冠状动脉搭桥术后血清肌钙蛋白I及肌酸激酶同工酶水平的变化,探讨两种术式心肌损伤的差异。方法选择36例行冠状动脉搭桥术患者,其中体外循环冠状动脉搭桥术组18例,非体外循环冠状动脉搭桥术组18例,分析两组肌钙蛋白I、肌酸激酶同工酶的血浆浓度变化。结果两组术前临床资料无显著性差异;体外循环冠状动脉搭桥术组术后观察期内血浆肌钙蛋白I及肌酸激酶同工酶较非体外循环冠状动脉搭桥术组明显升高(P<0.05)。结论非体外循环冠状动脉搭桥术组心肌损伤低于体外循环冠状动脉搭桥术组。 Objective To analyze the changes of cardiactroponin-Ⅰ and CK-MB between conventional on-pump coronary artery bypass grafting and off-pump coronary artery bypass grafting. Methods 36 patients received coronary artery bypass grafting,in which 18 received conventional on-pump coronary artery bypass grafting (group CCABG), and the other 18 received of Ppump coronary artery bypass grafting (group OPCAB). The changes of plasma cardiactroponin-Ⅰ and CK-MB were compared between two groups. Resuits There was no difference in the patient's data between two groups before surgery. In the observation period, the level of serum cardiactroponin-Ⅰ and CK-MB was much higher in group CCABG than that in group OPCAB(P〈0. 01). Conclusion The myocardial injury of off-pump coronary artery bypass grafting is lower than in Conventional on-pump coronary artery bypass grafting.
作者 王轩
机构地区 天津医科大学
出处 《青岛医药卫生》 2008年第2期90-92,共3页 Qingdao Medical Journal
关键词 冠状动脉搭桥术 肌钙蛋白Ⅰ 心肌损伤 Coronary artery bypass grafting Cardiactroponin-Ⅰ Myocardial injury
  • 相关文献

参考文献4

  • 1Kloner RA;Arimie RB;Kay GL.Evidence for stunned myocardium in humans:a 2001 update,2001(05).
  • 2何雪明,何忠良.心肌肌钙蛋白I在心脏外科围术期临床应用的研究进展[J].中华胸心血管外科杂志,2002,18(4):255-256. 被引量:11
  • 3Mair J;Lanue C;Mair P.Use of cardiac troponin I to diagnose perioperative mycardial infarction in coronary artery bypass grafting,1994(11).
  • 4Peivandi AA;Dahm M;Hake U.Pattens and diagnostic value of cardiac Troponin I vs troponin T and CK-MB after OPCAB surgery[J],2001(03).

二级参考文献1

共引文献10

同被引文献35

  • 1邵丽丽,刘萍,王明荣.体外循环心脏术后心肌损伤标志物的变化[J].重庆医学,2006,35(18):1645-1646. 被引量:13
  • 2Wojewodzka-Zelezniakowicz M, Chabielska E, Mogielnicki A, et al. Antithrombotic effect of tissue and plasma type angiotensin converting enzyme inhibitors in experimental thrombosis in rats[ J]. J Physiol Pharmacol,2006 ;57 (2) :231-45.
  • 3Kramkowski K, Mogielnicki A, Chabielska E, et al. The effect of 'tissue' and 'plasma' angiotensin converting enzyme inhibitors on overall haemostatic potentials in rats [ J ]. Thromb Res,2006 ; 117 ( 5 ) :557-61.
  • 4Claude L, Perol D, Ginestet C, et al. A prospective study on radiation pneumonitis following conformal radiation therapy in non-small-cell lung cancer:clinical and dosimetric factors analysis [ J ]. Radiother Oncol, 2004;71 (2) :175-81.
  • 5Venge P, Lagerqvist B, Diderholm E, et al. Clinical performance of three cardiac treponin assays in patients with unstable coronary artery disease( a FRISC II substudy) [ J]. Am J Cardiol.2002 ;89 ( 9 ) : 1035-41.
  • 6Wojewodzka--Zelezniakowicz M, Chabielska E, Mogielnicki A, et al. Antithrombotic effect of tissue and plasma type angiotensin con- verting enzyme inhibitors in experimental thrombosis in rats[J]. J Physiol Pharmacol,2006,57(2):231 -245.
  • 7Kramkowski K, Mogielnicki A, Chabielska E, et al. The effect of tissue" and 'plasma' angiotensin converting enzyme inhibitors on over all haemostatic potentials in rats [ J ]. Thromb Res, 2006,117 ( 5 ) 557--561.
  • 8Venge P, Lagerqvist B, DiderholmE, et al. Clinical performance of three cardiac troponin assays in patients with unstable coronary ar tery disease (a FRISC II substudy)[J]. Am J Cardiol,2002,89(9): 1035-- 1041.
  • 9Christenson R H, Azzazy H M. Biochemical markers of the acute coronary syndromes[J]. Clin Chem, 1998,44(8 Pt 2) : 1855-- 1864.
  • 10Behera S,Mangaraj M,Mohapatra PC.Diagnostic efficacy of ischemia modified albumin and its correlation with lipid profile, oxidative stress in acute myocardial infarct patients on admission. Asian Pac J Trop Dis . 2012

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...