期刊文献+

Low field microwave absorption and magnetization process in CoFeNi electroplated wires

Low field microwave absorption and magnetization process in CoFeNi electroplated wires
下载PDF
导出
摘要 Ferromagnetic resonance (FMR), Ferromagnetic antirresonance (FMAR) and low field magnetoimpedance (MI) are the characteristic features of high frequency losses in applied fields. While some results on FMR and FMAR in CoFeNi electroplated wires were reported earlier, here we present microwave absorption in CuBe wires electroplated by 1 μm FeCoNi magnetic layer at very low fields. These data are comparatively analysed together with longitudinal hysteresis loops in order to reveal the correlation between power absorption and magnetization processes. Microwave studies are made by using the cavity perturbation method at 9.65 GHz for a DC field parallel to the sample axis, and with microwave magnetic field hrf parallel or perpendicular to the wire axis. Two peaks have been observed in all samples, one is due to FMR, and the other is, at very low fields, related to MI. The MI peaks represent minima in power absorption. By comparing with the hysteresis loop we remark the close correspondence between the MI phenomena in the axial mode and the concomitant magnetization process. Ferromagnetic resonance (FMR), Ferromagnetic antirresonance (FMAR) and low field magnetoimpedance (MI) are the characteristic features of high frequency losses in applied fields. While some results on FMR and FMAR in CoFeNi electroplated wires were reported earlier, here we present microwave absorption in CuBe wires electroplated by 1 μm FeCoNi magnetic layer at very low fields. These data are comparatively analysed together with longitudinal hysteresis loops in order to reveal the correlation between power absorption and magnetization processes. Microwave studies are made by using the cavity perturbation method at 9.65 GHz for a DC field parallel to the sample axis, and with microwave magnetic field hrf parallel or perpendicular to the wire axis. Two peaks have been observed in all samples, one is due to FMR, and the other is, at very low fields, related to MI. The MI peaks represent minima in power absorption. By comparing with the hysteresis loop we remark the close correspondence between the MI phenomena in the axial mode and the concomitant magnetization process.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第4期1430-1435,共6页 中国物理B(英文版)
关键词 microwave absorption MAGNETOIMPEDANCE electroplated wires microwave absorption, magnetoimpedance, electroplated wires
  • 相关文献

参考文献22

  • 1Bozorth R M 1993 Ferromagnetism (New York: IEEE Press) p803.
  • 2Britel M R , Méard D, Melo L G , Ciureanu P, Yelon A, Cochrane R W and Cornut B 2000 J. Appl. Phys. 77 2737.
  • 3Srinivasu V V, Lofland S E, Bhagat S M, Ghosh K and Tyagi S D 1999 J. Appl. Phys. 86 1067.
  • 4Rinkevich A B, Nosov A P, Vasil'ev V G and Vladimirova E V 2004 Technical Physics 49 751.
  • 5Harrison E P, Turney G L, Rowe H and Gollop H 1937 Proc. Roy. Soc. 157 651.
  • 6Antonov A S , Gadetskiy S N, Granovskiy A B, Diachkov A L, Paramonov V P, Perov N S, Prokoshin A F, Usov N A and Lagar'kov A N 1997 Phys. Met. Metall. 83 60.
  • 7Liu L P, Zhao Z J, Zhang J C, Wu Z M, Ruan J Z, Wang Q J and Yang X L 2006 J. Magn. Magn. Mater. 305 212.
  • 8Fu C W and Zhang Z Q 2007 Chin. Phys. 16 1728.
  • 9Sangeeta Kale, Lofland S E, Bhagat S M, Garcfa-Miquel H, Ogale S B, Shinde S R and Venkatesan T 2002 J. Appl. Phys. 91 7736.
  • 10Lofland S E, Garcia-Miquel H, Vazquez M and Bhagat S M 2002 3. Appl. Phys. 92 2058.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部