期刊文献+

强γ背景下中子针孔成像的点扩展函数 被引量:1

Point spread function of neutron pinhole imaging in high gamma ray background
下载PDF
导出
摘要 利用基于Geant4建立起来的针孔成像模型获得了不同偏移量下γ与中子的好事例、能量沉积的比值,并模拟分析了强γ背景对中子针孔成像点扩展函数的影响。研究结果表明:在偏移量小于1cm时,γ与中子的好事例之比、γ与中子的能量沉积峰值之比以及γ与中子的能量沉积总和之比分别在0.40~0.42,0.63~0.65以及0.46~0.49之间;偏移量大于1cm时,比值下降明显,γ对中子的影响减小。在同一偏移量下,γ射线的点扩展函数的分布范围要比中子的小,两者叠加后所获得的点扩展函数的分布范围介于两者之间。在一定入射偏移范围内的成像质量优于在针孔中心位置入射时的成像质量。 The ratios of good event, energy deposition of gamma and neutron with different offsets are obtained by the model of pinhole imaging based on Geant4 system. The effect on the point spread function(PSF) of neutron pinhole imaging caused by the high gamma ray background is simulated and analyzed. The results show that with the offsets less than 1 cm the ratios of good event, peak value of energy deposition, total energy deposition of gamma and neutron are 0.40~0.42, 0.63~0.65, 0.46~0.49, respectively; with the offsets greater than 1 cm the ratios fall obviously, i.e., the impact of gamma on neutron decreases. With the same offset, the distribution of PSF of gamma is smaller than that of neutron, and the distribution of PSF of the two particles’ superposition is between that of gamma and that of neutron. Images obtained in with a certain incident offset have better quality than that of incidence from the center position.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2008年第3期517-520,共4页 High Power Laser and Particle Beams
基金 国防科技基础研究基金资助课题 国家自然科学基金资助课题(10575140,60602065) 重庆市自然科学基金资助课题(8562) 国家973重大基础研究项目(2003CB716300)
关键词 中子针孔成像 点扩展函数 强γ背景 GEANT4 Neutron pinhole imaging Point spread function High gamma ray background Geant4
  • 相关文献

参考文献10

  • 1Nakashima P N H, Johnson A W S. Measuring the PSF from aperture images of arbitrary shape-an algorithm[J]. Ultramicroscopy, 2003, 94(2) : 135-148.
  • 2Moran M, Haan S, Hatehett S, et al. Downseattered neutron imaging[J]. Rev Sci Instrum, 2004, 75(10):3592-3594.
  • 3孔祥龙,李玉同,远晓辉,于全芝,郑志远,梁文锡,王兆华,魏志义,张杰.Lucy-Richardson算法用于针孔图像的恢复[J].物理学报,2006,55(5):2364-2370. 被引量:20
  • 4Jeanneau F, Junca R, Pancin J, et al. Neutron imaging with a micromegas detector[J]. IEEE Transactions on Nuclear Science, 2006, 53 (2) :595- 600.
  • 5章法强,李正宏,杨建伦,杨洪琼,叶凡,应纯同,刘广均.快中子照相中的点扩展函数计算[J].强激光与粒子束,2006,18(7):1183-1185. 被引量:6
  • 6蒋敏,胡炳全,马庆力,唐世彪,方祯云,曾代敏.中子针孔成像点扩展函数模拟研究[J].光子学报,2008,37(2):310-313. 被引量:4
  • 7Agostinelli S, Allison J, Amako K, et al. Geant4-a simulation toolkit[J]. Nucl Instr and Meth in Phys Res A, 2003, 506(3):250-303.
  • 8Physics reference manual at the Geant4[OL]. http://geant4.web. cern. ch/geant4.
  • 9Bicron corporation website[OL].http://www.bicron.com.
  • 10陈法新,郑坚,杨建伦.中子厚针孔成像数值模拟研究[J].物理学报,2006,55(11):5947-5952. 被引量:15

二级参考文献36

共引文献38

同被引文献12

  • 1吴刚,李泉凤,程诚,杜泰斌,黑东炜,罗剑辉.厚针孔成像动态监测高能加速器束斑系统[J].高能物理与核物理,2005,29(1):86-90. 被引量:4
  • 2Takahashi T,Watanabe S.Recent progress in CdTe and CdZnTe detectors[J].IEEE Trans on Nucl Sci,2001,48(4):950-958.
  • 3Zeniya T,Watabe H,Aoi T,et al.3D image reconstruction using complete data in pinhole SPECT[C]//IEEE Nuclear Science Symposium Conference Record.2003.
  • 4Van der Have F,Beekman F J.Penetration and scatter in channel micropinholes for SPECT:a Monte Carlo investigation[J].IEEE Trans on Nucl Sci,2006,53(5):2635-2645.
  • 5Bal G,Zeng G L,Lewitt T M,et al.Study of different pinhole configurations for small animal tumor imaging[C]//IEEE Nuclear Science Symposium Conference Record.2004.
  • 6Vadawale S V,Hong J,Grindlay J,et al.Multipixel characterization of imaging CZT detectors for hard X-ray imaging and spectroscopy[C]//Proc of SPIE.2004,5540:22-32.
  • 7Yu Pengfei,Jie Wanqi,Wang Tao,et al.Thermal treatment of indium-doped Cd1-xZnxTe single crystals[J].Crystal Growth,2009,311:1268-1272.
  • 8Kuvvetli I,Budtz-Jrgensen C.Pixelated CdZnTe drift detectors[J].IEEE Trans on Nucl Sci,2005,52(5):1975-1981.
  • 9Mark B W,Alexander V S,Bijoy K K.Investigation of spatial resolution and efficiency using pinholes with small pinhole angle[C]//IEEE Nuclear Science Symposium Conference Record.2002.
  • 10Metzler S D,Bowsher J E,Smith M F,et al.Analytic determination of pinhole collimator sensitivity with penetration[J].IEEE Trans on Medical Imaging,2001,20(8):730-741.

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部