期刊文献+

荧光分光光度法测大黄中总蒽醌的含量 被引量:8

Spectrofluorimetric determination of total anthraquinone content in Chinese Rheum
下载PDF
导出
摘要 目的建立一种快速、简单、灵敏度高,测定大黄中总蒽醌的含量的荧光分光光度法。方法于10.0 ml比色管中加入一定量的1,8-二羟基蒽醌标准溶液,pH值为3.60的NaAc-HAc缓冲溶液2.0 ml,有机溶剂乙腈2.0ml,最后定容至10.0 ml;同时做空白对照,在最大激发波长为440 nm,最大发射波长为521 nm处测定一系列溶液的荧光强度。结果荧光强度与蒽醌的含量在0.0091-15.0μg/ml范围内呈良好的线性关系。用于大黄中总蒽醌的含量测定,结果令人满意。结论荧光分光光度法成功用于大黄中总蒽醌的含量测定。 Objective: To develop a simple,rapid,sensitive and selective spectrofluorimetric method to determine Rheum total anthraquinone content.Methods: Into a series of 10 ml colorimetric tube were added different aliquots of the 1,8-dihydroxyanthraquinone standard solution,2.0 ml of NaAc-HAc buffer solution(pH=3.60),2.0 ml of ethylacetate.The mixture was diluted to the mark with doubly distilled water.Then the fluorescent intensity of the solution was measured at 440/521 nm against a reagent blank.Results: The linear range was 0.0091~15.0 μg/ml.Conclusion: The proposed method is successfully in the determination of Rheum total anthraquinone content spectrofluorimetry.
机构地区 泰山医学院
出处 《泰山医学院学报》 CAS 2008年第1期36-40,共5页 Journal of Taishan Medical College
关键词 荧光分光光度法 大黄 蒽醌 spectrofluorimetry Chineserhubarb anthraquinone
  • 相关文献

参考文献10

二级参考文献56

共引文献177

同被引文献101

引证文献8

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部