摘要 目的探讨用高效液相色谱(HPLC)法测定异烟肼注射液的含量。方法采用DiamonsilC18色谱柱(250mm×4.6m m,5μm),流动相为甲醇-水(20∶80),检测波长为263nm,流速为1.0mL/min。结果进样量与峰面积的线性范围为0.202~1.01μg(r=0.9998),平均回收率为99.53%,RSD为0.36%(n=6)。结论HPLC法简便、准确、灵敏度高,重现性好,可用于异烟肼注射液的含量测定。 Objective To establish a method for the determination of Isoniazid Injection by HPLC. Methods Diamonsil C18 5μ column(250mm × 4.6 μm)was used. The mobile phase was methanol-water(20 : 80).The detection wavelength was set at 263 nm, the flow rate was 1.0 mL/min. Results The linear range of hydrochloride was 0. 202 - 1.01 μg( r =0. 999 8), the average recovery rate was 99. 53%, RSD was 0. 36% (n=6). Conclusion The method is simple, and accurate with, higher sensitivity and good reproducibility. This method can be used for the content determination of Isoniazid Injection.
作者 黎昌权
出处 《中国药业》 CAS 2008年第8期32-33,共2页 China Pharmaceuticals
关键词 高效液相色谱法 异烟肼注射液 含量测定 HPLC Isoniazid Injection content determination