期刊文献+

夏热冬冷地区建筑围护结构双面保温设计的构想

Design of Double Side Thermal Insulation of Building Envelope Structure in Hot Summer and Winter Cold Zones
下载PDF
导出
摘要 通过对当前普遍采用的建筑外墙内保温、夹心保温及外保温技术的利弊的探讨,分析居住建筑采暖(空调)运行的模式、住宅建筑特点以及气候特征,提出适应夏热冬冷地区间歇采暖(空调)条件下双面保温构造设计的构想。在等效热阻条件下,选取4种间歇空调模式进行实验房测试。从墙体热工性能、室内热环境状况和空调能耗3个方面,评价双面保温与外保温的优劣。 The advantages and disadvantages of the thermal insulation technology for outer-wall were discussed, which includes external insulation, internal insulation and middle insulation. The residential building heating and air-conditioning operation mode, residential building and the climate characteristicswere analyzed. The double side insulation design to adapt the intermittent heating and air-conditioning opera- tion mode in hot summer and cold winter zones were proposed. Under the condition of the equivalent thermal resistance, four intermittent air- conditioning operation modes were measured. From the three aspects of wall thermal performance, indoor thermal environment and air-conditioning consumption, double side thermal insulation was compared with external thermal insulation.
作者 王沛 丁小中
出处 《建筑节能》 CAS 2008年第4期33-35,74,共4页 BUILDING ENERGY EFFICIENCY
关键词 外墙外保温 内保温 冷(热)桥 间歇模式 双面保温 external thermal insulation for outer-wall internal thermal insulation cold/thermal bridge intermittent mode double side insulation