期刊文献+

Monte-Carlo simulation of a compact gamma-ray detector using wavelength-shifting fibers coupled to a YAP scintillation crystal 被引量:1

Monte-Carlo simulation of a compact gamma-ray detector using wavelength-shifting fibers coupled to a YAP scintillation crystal
原文传递
导出
摘要 The production and transportation of fluorescent light produced in wavelength-shifting fibers (WSFs) coupled to YAP scintillation crystal is simulated using the GEANT4 codes. An advantage of the wavelength-shifting fiber readout technique over a direct readout with a position-sensitive photo-sensor is the reduced requirement for position sensitive photomultiplier tube photocathode area. With this gamma-ray detector, the gamma camera is small and flexible and has larger effective field of view and low cost. Simulation results show that a) a mean 12 of photons per 59.5 keV gamma ray interaction is produced in the WSF located nearest to the incident gamma ray, and a spatial resolution of 3.6 mm FWHM is obtained, b) a mean 27 of photons per 140 keV gamma ray interaction is produced and a spatial resolution of 3.1 mm FWHM is obtained. Results demonstrate the feasibility of this concept of a compact gamma-ray detector based on wavelength-shifting fibers readout. However, since the very low photoelectron levels, it is very important to use a photon counting device with good single photo-electron response to readout the WSFs. The production and transportation of fluorescent light produced in wavelength-shifting fibers (WSFs) coupled to YAP scintillation crystal is simulated using the GEANT4 codes. An advantage of the wavelength-shifting fiber readout technique over a direct readout with a position-sensitive photo-sensor is the reduced requirement for position sensitive photomultiplier tube photocathode area. With this gamma-ray detector, the gamma camera is small and flexible and has larger effective field of view and low cost. Simulation results show that a) a mean 12 of photons per 59.5 keV gamma ray interaction is produced in the WSF located nearest to the incident gamma ray, and a spatial resolution of 3.6 mm FWHM is obtained, b) a mean 27 of photons per 140 keV gamma ray interaction is produced and a spatial resolution of 3.1 mm FWHM is obtained. Results demonstrate the feasibility of this concept of a compact gamma-ray detector based on wavelength-shifting fibers readout. However, since the very low photoelectron levels, it is very important to use a photon counting device with good single photo-electron response to readout the WSFs.
出处 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第5期377-380,共4页 中国物理C(英文版)
基金 National Nature Science Foundation of China(10275063)
关键词 Monte-Carlo simulation WSF spatial resolution Monte-Carlo simulation, WSF, spatial resolution
  • 相关文献

参考文献1

二级参考文献3

共引文献7

同被引文献14

  • 1QI Yu-Jin.High-resolution SPECT for small-animal imaging[J].Nuclear Science and Techniques,2006,17(3):164-169. 被引量:3
  • 2Robert S,Gary R.Current status and requirements for position-sensitive detectors in medicine. Nuclear Instruments . 2002
  • 3Belcari N,Camarda M,Guerra D,et al.Detector development for a novel Positrion Emission Mammography scanner based on YAP:Ce crystal. Nuclear Instruments . 2004
  • 4Bakkali A,Tamada N,Parmentier M,et al.Monte Carlo simulation of discrete gamma-ray detectors. Nuclear Instruments . 2005
  • 5Tamda N,Bakkali A,Boulahdour H,et al.Feasibility study of a gamma-ray detector based on square PSPMT array for breast cancer imaging. Nuclear Instruments . 2006
  • 6Antoccia A,Baldazzi G,Banzato A,et al.A YAP camera for the biodistribution of 188Re conjugated with Hyaluronic-Acid in"in vivo" systems. Nucl Instrum Methods Phys A . 2007
  • 7Brem R F,Kieper D A,Rapelyea J A,et al.Evaluation of a highresolution,breast-specific,small-field-of-view gamma camera for the detection of breast cancer. Nucl Instrum Methods Phys A . 2003
  • 8More J,Goodale J,Majewski S,et al.Evaluation of gamma cameras for use in dedicated breast imaging. IEEE Transactions on Nuclear Science . 2006
  • 9Loudos G,Majewski S,Wojcik R,et al.Performance evaluation of a mouse-sized camera for dynamic studies in small animals. Nucl Instrum Methods Phys A . 2007
  • 10GEANT4 website<http://geant4.web.cern.ch/geang4> .

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部