摘要
通过观察退火炉气体发生器U型辐射管断裂现象,从材质、外观、金相、工艺方面进行了技术分析,提出了改进措施。
By observing the broken of U- pattern radiation tube of air generator of annealing furnace, the technical analysis is done from fields of material, outward appearance, metallography and process, some measures proposed.
出处
《河北冶金》
2008年第2期34-35,37,共3页
Hebei Metallurgy
关键词
退火炉
发生器
辐射管
断裂
annealing furnace
generator
radiation tube
broken