摘要 本文基于二滩拱坝坝体监测仪器的温度观测资料,采用有限元法对坝体温度场进行了反馈分析。通过与实测温度值的比较,表明反馈温度值与实测值基本吻合,基本可以反映坝体实际温度场的分布情况,对于深入了解特高拱坝运行期坝体混凝土的实际温度变化具有重要的意义。从反馈温度场可以看出,由于二滩拱坝坝轴线方向接近南北方向,使得冬季时下游坝面温度明显呈现左右岸不对称分布,与规范设计温度荷载有很大差别,值得注意。 A lot of temperature data of Ertan arch dam have been recorded by the monitoring instruments installed within the dam body since its completion in 1998. Based on these measured data, feedback analysis of temperature field of Ertan arch dam is carried out by using the finite element method in this paper. Comparisons with the recorded temperatures show that the feedback temperatures agree well with the measured temperatures and display the actual temperature distribution in the dam body. The feedback analysis shows that the temperature field of the downstream face is nonsymmetric about the center line of arch dam in winter because the axis of dam approximates to the north-south direction. It should be noted that this temperature load is clearly different from the designed temperature load.
出处 《水力发电学报》 EI CSCD 北大核心 2008年第2期65-70,共6页 Journal of Hydroelectric Engineering
基金 国家自然科学基金委员会和二滩水电开发有限责任公司雅砻江水电开发联合研究基金项目(50539020)
关键词 水工结构 温度场 反馈分析 二滩拱坝 原型观测资料 hydraulic structure temperature field feedback analysis Ertan arch dam monitoring data
  • 相关文献

参考文献6

二级参考文献5

  • 1电力工业部中南勘测设计研究院.水工建筑物荷载设计规范(DL 5077-1997)[S].北京:中国电力出版社,1998..
  • 2水利电力部华东勘测设计院.混凝土拱坝设计规范(SL 145-85)[S].北京:水利电力出版社,1985..
  • 3能源部 水利部.混凝土大坝安全监测技术规范(SDJ336-89)[S].北京:水利电力出版社,1989年..
  • 4王锋辉.二滩水电站绕坝渗流监测系统改造[J].大坝监测技术,2002,(4).
  • 5赵志仁,赵永.水利水电工程安全监测设计优化的研究[J].大坝观测与土工测试,2000,24(5):4-6. 被引量:10

共引文献29

同被引文献142

引证文献10

二级引证文献77

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部