在役换热器管漏磁内检测传感器设计 被引量:2

Design of Magnetic Flux Leakage In-line Testing Tools for In-Service Heat Exchanger Tubes
下载PDF
导出
摘要 根据漏磁检测基本原理,研制了在役换热器管漏磁内检测传感器,包括磁化方式和检测元件的选取等.并在38 mm的换热管上进行了详细实验,结果表明该传感器可有效检测出1.6 mm的通孔、20%的外壁截面积损失和20%壁厚深度圆锥盲孔.该装置具有检测灵敏度高,性能可靠的优点,有较好的应用前景. Heat exchanger tubes are the key components in industries and their failure cause large economic loss. It is important to research on the in-service inspection method of ferromagnetic tubes. One type of inline testing tools for in-service ferromagnetic heat exchanger tubes was developed according to the principle of magnetic flux leakage testing. Selection of magnetization method and magnetic sensor is studied. The detailed test was employed on the diameter 38mm of tubes. Testing results indicated that the tool can test down hole diameter 1.6mm, 20% metallic area loss of outer wall and 20% cone hole depth of wall thickness. It will be employed for its high sensitivity and reliable performance.
出处 《湖北工业大学学报》 2008年第1期5-9,共5页 Journal of Hubei University of Technology
基金 国家自然科学基金资助(5067508)
关键词 铁磁性换热器管 漏磁检测 无损检测 缺陷 heat exchanger tube magnetic flux leakage testing nondestructive testing defectl
  • 相关文献

参考文献3

二级参考文献5

  • 1陶旺斌 周在杞.电磁检测[M].北京:航空工业出版社,1994.154—194.
  • 2Selection of NDT Techniques for Inspection of Heat Exchanger Tubing,Anmol S.Birring,The ASNT International Conference on Petroleum Industry Inspection,1999
  • 3Birring Anmol S.Selection of NDT techniques for inspection of heat exchanger tubing[A].The ASNT International Conference on Petroleum Industry Inspection[C].HOUSTON,Texas:ASNT,1999.
  • 4Walter Matulewicz,Gilles Rousseau.Recent advances in carbon steel tube inspection[A].The ASNT International Conference on Petroleum Industry Inspection[C].HOUSTON,Texas:ASNT,1999.
  • 5陶旺斌,周在杞.电磁检测[M].北京:航空工业出版社,1994.

共引文献12

同被引文献10

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部