摘要 针对经絮凝剂聚合氯化铝预处理之后的造纸厂缺氧/好氧(A/O)污水处理系统二沉池出水,采用中试规模的连续微滤(CMF)和反渗透(RO)集成工艺进行深度处理,研究了CMF+RO集成工艺的处理效果.试验结果表明,CMF产水各项指标满足RO进水要求,CODCr平均87.7 mg/L,悬浮固体3.1 mg/L,浊度0.17 NTU,色度23.4 PCU,去除率分别高达39%、85.7%、98.3%和48.2%;RO产水CODCr平均3.2 mg/L,浊度0.07NTU,色度4.1 PCU,电导率41.8μS/cm,脱盐率高达99%,满足造纸工艺回用水的要求. A pilot-scaled continuous membrane filtration (CMF) and reverse osmosis integrated technics is used for the treatment of secondary sedimentation tank effluent in an anaerobic/aerobic treatment system from a paper mill after pretreated by using PAC as flocculant. The results show that the CMF permeate satisfies all requirements of RO influent, which CODCr, SS, turbidity and chroma are 87.7 mg/L, 3.1 mg/L, 0.17 NTU and 23.4 PCU on average respectively, and the removals of CODa, SS, turbidity and chroma are high to 39%, 85.7%, 98.3% and 48.2% by the CMF system. RO permeate meets the requirements of water quality for paper manufacturing in every aspects, which CODc,, turbidity and chroma is 3.2 mg/L, 0.07 NTU and 4.1 PCU on average respectively, conductivity is less than 41.8μS/cm, and salts rejection is high to 99%.
出处 《天津工业大学学报》 CAS 2008年第2期44-47,共4页 Journal of Tiangong University
关键词 连续微滤 反渗透 膜集成工艺 水回用 continuous membrane filtration reverse osmosis integrated membrane technology water reuse
  • 相关文献

参考文献3

  • 1国家环保总局.中国环境统计年报[M].北京:中国环境科学出版社,2005.11.
  • 2赵岳轩,温建志,王爱民,李文国,张海霞.膜技术在造纸废水回用中的应用研究[J].化工时刊,2005,19(8):31-32. 被引量:8
  • 3GRADY C P L, HARLOW L J, RIESING R R. Effects of growth rate and influent substrate concentration of effluent quality from chemostats containing bacteria in pure and mixed culture [J]. Biotechnol Bioeng, 1972,14: 391-410.

二级参考文献3

共引文献7

同被引文献263

引证文献20

二级引证文献100

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部