摘要
介绍了台州发电厂6台N125MW机组的改造情况,比较分析了三维、四维技术与东芝技术的特点及其效率试验情况,提出了设计优化措施,对其他电厂的机组改造具有借鉴意义。
The retrofitting conditions of six N125 MW units in Taizhou power plant were introduced. The characteristics and efficiency test results of three & four-dimension technology and TOSHIBA technology were compared and analyzed. The optimized designing measures were put forward which provided good reference for the other units.
出处
《能源工程》
2008年第2期56-60,共5页
Energy Engineering
关键词
通流部分
改造
设计特点
运行状况
turbine steam passage
retrofitting
design characteristics
operating conditions